{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-0864","assignerOrgId":"2b718523-d88f-4f37-9bbd-300c20644bf9","state":"PUBLISHED","assignerShortName":"ABB","dateReserved":"2023-02-16T13:04:48.837Z","datePublished":"2023-05-17T07:15:52.371Z","dateUpdated":"2025-01-22T16:50:21.453Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Terra AC wallbox (UL40/80A)","vendor":"ABB","versions":[{"lessThanOrEqual":"1.5.5","status":"affected","version":"1.0;0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Terra AC wallbox (UL32A) ","vendor":"ABB","versions":[{"lessThanOrEqual":"1.6.5","status":"affected","version":"1.0;0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Terra AC wallbox (CE)  (Terra AC MID)","vendor":"ABB","versions":[{"lessThanOrEqual":"1.6.5","status":"affected","version":"1.0;0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Terra AC wallbox (CE)  Terra AC Juno CE","vendor":"ABB","versions":[{"lessThanOrEqual":"1.6.5","status":"affected","version":"1.0;0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Terra AC wallbox (CE) Terra AC PTB ","vendor":"ABB","versions":[{"lessThanOrEqual":"1.5.25","status":"affected","version":"1.0;0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Terra AC wallbox (CE) Symbiosis","vendor":"ABB","versions":[{"lessThanOrEqual":"1.2.7","status":"affected","version":"1.0;0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Terra AC wallbox (JP)","vendor":"ABB","versions":[{"lessThanOrEqual":"1.6.5","status":"affected","version":"1.0;0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"ABB acknowledges and thanks Andi Leach and Puck Meerburg who responsibly disclosed these vulnerabilities and provided valuable input on product improvements. ABB also acknowledges and thanks Lionel R. Saposnik from Saiflow who also responsibly disclosed these vulnerabilities and provided valuable input on product improvements."}],"datePublic":"2023-05-16T18:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Cleartext Transmission of Sensitive Information vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).<p>This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.</p>"}],"value":"Cleartext Transmission of Sensitive Information vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":7.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-319","description":"CWE-319 Cleartext Transmission of Sensitive Information","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"2b718523-d88f-4f37-9bbd-300c20644bf9","shortName":"ABB","dateUpdated":"2023-05-17T07:15:52.371Z"},"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=9AKK108468A1415&LanguageCode=en&DocumentPartId=&Action=Launch"}],"source":{"discovery":"UNKNOWN"},"title":"Configuration data is exchanged in plaintext and could be available to a nearby attacker if present during configuration or usage of the device via Bluetooth Low Energy (BLE).","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T05:24:34.668Z"},"title":"CVE Program Container","references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=9AKK108468A1415&LanguageCode=en&DocumentPartId=&Action=Launch","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-01-22T16:49:48.531006Z","id":"CVE-2023-0864","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-01-22T16:50:21.453Z"}}]}}