{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"state":"PUBLISHED","cveId":"CVE-2022-48522","assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","dateUpdated":"2026-10-14T18:44:27.849Z","dateReserved":"2023-07-23T00:00:00.000Z","datePublished":"2023-08-22T00:00:00.000Z"},"containers":{"cna":{"providerMetadata":{"orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre","dateUpdated":"2023-09-15T13:06:20.633Z"},"descriptions":[{"lang":"en","value":"In Perl 5.34.0, function S_find_uninit_var in sv.c has a stack-based crash that can lead to remote code execution or local privilege escalation."}],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":[{"url":"https://github.com/Perl/perl5/blob/79a7b254d85a10b65126ad99bf10e70480569d68/sv.c#L16336-L16345"},{"url":"https://security.netapp.com/advisory/ntap-20230915-0008/"}],"problemTypes":[{"descriptions":[{"type":"text","lang":"en","description":"n/a"}]}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T15:17:55.174Z"},"title":"CVE Program Container","references":[{"url":"https://github.com/Perl/perl5/blob/79a7b254d85a10b65126ad99bf10e70480569d68/sv.c#L16336-L16345","tags":["x_transferred"]},{"url":"https://security.netapp.com/advisory/ntap-20230915-0008/","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-03T14:20:55.608211Z","id":"CVE-2022-48522","options":[{"Exploitation":"poc"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-10-03T14:21:12.055Z"}},{"x_adpType":"supplier","providerMetadata":{"orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP","dateUpdated":"2026-10-14T18:44:27.849Z"},"affected":[{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.0","lessThan":"V3.1.5","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.0","lessThan":"V3.1.5","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.0","lessThan":"V3.1.5","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.0","lessThan":"V3.1.5","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.0","lessThan":"V3.1.5","versionType":"custom"}],"defaultStatus":"unknown"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-398330.html"}]}]}}