{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-47936","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2022-12-23T11:29:16.433Z","datePublished":"2023-02-14T10:36:21.369Z","dateUpdated":"2025-03-20T20:07:30.206Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2023-02-15T09:24:56.841Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."}],"affected":[{"vendor":"Siemens","product":"JT Open","versions":[{"version":"All versions < V11.2.3.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"JT Utilities","versions":[{"version":"All versions < V13.2.3.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V34.0","versions":[{"version":"All versions < V34.0.252","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V34.1","versions":[{"version":"All versions < V34.1.242","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V35.0","versions":[{"version":"All versions < V35.0.170","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V35.1","versions":[{"version":"All versions < V35.1.150","status":"affected"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.8,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-121","description":"CWE-121: Stack-based Buffer Overflow","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T15:02:36.549Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-03-20T20:07:21.772715Z","id":"CVE-2022-47936","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-03-20T20:07:30.206Z"}}]}}