{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-46670","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","state":"PUBLISHED","assignerShortName":"Rockwell","requesterUserId":"20b06643-9bf3-4d1d-a98d-f8db99f95a31","dateReserved":"2022-12-06T15:27:58.542Z","datePublished":"2022-12-16T20:12:22.414Z","dateUpdated":"2025-04-17T14:35:29.173Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"MicroLogix 1100 & 1400 Controllers","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"All"}]},{"defaultStatus":"unaffected","product":"MicroLogix 1400-B/C","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"21.007 and below"}]},{"defaultStatus":"unaffected","product":"MicroLogix 1400-A","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"7.000 and below"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Ryan Pickren, a security researcher from Georgia Institute of Technology"}],"datePublic":"2022-12-13T15:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute&nbsp;of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. &nbsp;The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. </span>\n\n"}],"value":"\nRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.  The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \n\n"}],"impacts":[{"capecId":"CAPEC-63","descriptions":[{"lang":"en","value":"CAPEC-63 Cross-Site Scripting (XSS)"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":7.1,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"b73dd486-f505-4403-b634-40b078b177f0","shortName":"Rockwell","dateUpdated":"2022-12-16T20:12:22.414Z"},"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679"}],"source":{"discovery":"UNKNOWN"},"title":"Rockwell Automation MicroLogix 1100 & 1400 Vulnerable to Cross-Site Scripting Attack","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T14:39:38.680Z"},"title":"CVE Program Container","references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-17T14:35:20.399901Z","id":"CVE-2022-46670","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-04-17T14:35:29.173Z"}}]}}