{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"state":"PUBLISHED","cveId":"CVE-2022-44457","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","dateUpdated":"2025-05-01T18:07:21.381Z","dateReserved":"2022-10-31T00:00:00.000Z","datePublished":"2022-11-08T00:00:00.000Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2022-12-13T00:00:00.000Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.0 < V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.1 < V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration."}],"affected":[{"vendor":"Siemens","product":"Mendix SAML (Mendix 7 compatible)","versions":[{"version":"All versions < V1.17.0","status":"affected"}]},{"vendor":"Siemens","product":"Mendix SAML (Mendix 7 compatible)","versions":[{"version":"All versions >= V1.17.0 < V1.17.2","status":"affected"}]},{"vendor":"Siemens","product":"Mendix SAML (Mendix 8 compatible)","versions":[{"version":"All versions < V2.3.0","status":"affected"}]},{"vendor":"Siemens","product":"Mendix SAML (Mendix 8 compatible)","versions":[{"version":"All versions >= V2.3.0 < V2.3.2","status":"affected"}]},{"vendor":"Siemens","product":"Mendix SAML (Mendix 9 compatible, New Track)","versions":[{"version":"All versions < V3.3.1","status":"affected"}]},{"vendor":"Siemens","product":"Mendix SAML (Mendix 9 compatible, New Track)","versions":[{"version":"All versions >= V3.3.1 < V3.3.5","status":"affected"}]},{"vendor":"Siemens","product":"Mendix SAML (Mendix 9 compatible, Upgrade Track)","versions":[{"version":"All versions < V3.3.0","status":"affected"}]},{"vendor":"Siemens","product":"Mendix SAML (Mendix 9 compatible, Upgrade Track)","versions":[{"version":"All versions >= V3.3.0 < V3.3.4","status":"affected"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf"}],"problemTypes":[{"descriptions":[{"type":"CWE","lang":"en","description":"CWE-294: Authentication Bypass by Capture-replay","cweId":"CWE-294"}]}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T13:54:03.401Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf","tags":["x_transferred"]}]},{"metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":9.8,"attackVector":"NETWORK","baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"HIGH"}},{"other":{"type":"ssvc","content":{"timestamp":"2025-05-01T18:07:08.237002Z","id":"CVE-2022-44457","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-05-01T18:07:21.381Z"}}]}}