{"dataType":"CVE_RECORD","cveMetadata":{"state":"PUBLISHED","cveId":"CVE-2022-43110","assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","dateUpdated":"2025-08-22T20:25:23.662Z","dateReserved":"2022-10-17T00:00:00.000Z","datePublished":"2025-08-22T00:00:00.000Z"},"containers":{"cna":{"providerMetadata":{"orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre","dateUpdated":"2025-08-22T19:34:35.786Z"},"descriptions":[{"lang":"en","value":"Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down."}],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":[{"url":"https://www.ready2disclose.com/vpow-31491-43110/"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-182-05"}],"problemTypes":[{"descriptions":[{"type":"text","lang":"en","description":"n/a"}]}]},"adp":[{"problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-425","lang":"en","description":"CWE-425 Direct Request ('Forced Browsing')"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-306","lang":"en","description":"CWE-306 Missing Authentication for Critical Function"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-284","lang":"en","description":"CWE-284 Improper Access Control"}]}],"metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":9.8,"attackVector":"NETWORK","baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"HIGH"}},{"other":{"type":"ssvc","content":{"timestamp":"2025-08-22T20:23:45.457505Z","id":"CVE-2022-43110","options":[{"Exploitation":"poc"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-08-22T20:25:23.662Z"}}]},"dataVersion":"5.1"}