{"containers":{"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"Crestron AirMedia for Windows before 5.5.1.84 has insecure inherited permissions, which leads to a privilege escalation vulnerability found in the AirMedia Windows Application, version 4.3.1.39. A low privileged user can initiate a repair of the system and gain a SYSTEM level shell."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2022-09-22T23:30:16.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"tags":["x_refsource_MISC"],"url":"https://www.crestron.com/Security/Security_Advisories"},{"tags":["x_refsource_MISC"],"url":"https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2022-40298","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Crestron AirMedia for Windows before 5.5.1.84 has insecure inherited permissions, which leads to a privilege escalation vulnerability found in the AirMedia Windows Application, version 4.3.1.39. A low privileged user can initiate a repair of the system and gain a SYSTEM level shell."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"https://www.crestron.com/Security/Security_Advisories","refsource":"MISC","url":"https://www.crestron.com/Security/Security_Advisories"},{"name":"https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf","refsource":"MISC","url":"https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T12:14:40.215Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.crestron.com/Security/Security_Advisories"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"}]},{"problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-732","lang":"en","description":"CWE-732 Incorrect Permission Assignment for Critical Resource"}]}],"metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":8.8,"attackVector":"NETWORK","baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"LOW","confidentialityImpact":"HIGH"}},{"other":{"type":"ssvc","content":{"timestamp":"2025-05-27T15:22:47.788281Z","id":"CVE-2022-40298","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-05-27T15:23:18.955Z"}}]},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2022-40298","datePublished":"2022-09-22T23:30:16.000Z","dateReserved":"2022-09-08T00:00:00.000Z","dateUpdated":"2025-05-27T15:23:18.955Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}