{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"state":"PUBLISHED","cveId":"CVE-2022-39157","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","dateUpdated":"2025-04-21T13:47:13.547Z","dateReserved":"2022-09-01T00:00:00.000Z","datePublished":"2022-11-08T00:00:00.000Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2023-02-15T09:24:49.998Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.0 (All versions >= V34.0.252 < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V34.1 (All versions >= V34.1.242 < V34.1.244), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.0 (All versions >= V35.0.170 <  V35.0.184), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)"}],"affected":[{"vendor":"Siemens","product":"Parasolid V34.0","versions":[{"version":"All versions < V34.0.252","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V34.0","versions":[{"version":"All versions >= V34.0.252 < V34.0.254","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V34.1","versions":[{"version":"All versions < V34.1.242","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V34.1","versions":[{"version":"All versions >= V34.1.242 < V34.1.244","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V35.0","versions":[{"version":"All versions < V35.0.170","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V35.0","versions":[{"version":"All versions >= V35.0.170 <  V35.0.184","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Simcenter Femap","versions":[{"version":"All versions < V2023.1","status":"affected"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.8,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-125","description":"CWE-125: Out-of-bounds Read","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf"}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T11:10:32.613Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-18T15:22:35.932896Z","id":"CVE-2022-39157","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-04-21T13:47:13.547Z"}}]}}