{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"state":"PUBLISHED","cveId":"CVE-2022-38767","assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","dateUpdated":"2026-04-14T08:58:05.041Z","dateReserved":"2022-08-25T00:00:00.000Z","datePublished":"2022-11-25T00:00:00.000Z"},"containers":{"cna":{"providerMetadata":{"orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre","dateUpdated":"2022-11-25T00:00:00.000Z"},"descriptions":[{"lang":"en","value":"An issue was discovered in Wind River VxWorks 6.9 and 7, that allows a specifically crafted packet sent by a Radius server, may cause Denial of Service during the IP Radius access procedure."}],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":[{"url":"https://windriver.com"},{"url":"https://support2.windriver.com/index.php?page=cve&on=view&id=CVE-2022-38767"}],"problemTypes":[{"descriptions":[{"type":"text","lang":"en","description":"n/a"}]}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T11:02:14.648Z"},"title":"CVE Program Container","references":[{"url":"https://windriver.com","tags":["x_transferred"]},{"url":"https://support2.windriver.com/index.php?page=cve&on=view&id=CVE-2022-38767","tags":["x_transferred"]}]},{"problemTypes":[{"descriptions":[{"type":"CWE","lang":"en","description":"CWE-noinfo Not enough information"}]}],"metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":7.5,"attackVector":"NETWORK","baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","integrityImpact":"NONE","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"NONE"}},{"other":{"type":"ssvc","content":{"timestamp":"2025-04-25T18:43:40.135126Z","id":"CVE-2022-38767","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-04-25T18:44:18.928Z"}},{"x_adpType":"supplier","providerMetadata":{"orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP","dateUpdated":"2026-04-14T08:58:05.041Z"},"affected":[{"vendor":"Siemens","product":"SIPROTEC 5 6MD85 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 6MD86 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 6MD89 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.64","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 6MU85 (CP300)","versions":[{"status":"affected","version":"V7.90","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7KE85 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7SA86 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7SA87 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7SD86 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7SD87 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7SJ85 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7SJ86 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7SK85 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7SL86 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7SL87 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7SS85 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7ST85 (CP300)","versions":[{"status":"affected","version":"V8.81","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7ST86 (CP300)","versions":[{"status":"affected","version":"V9.20","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7SX85 (CP300)","versions":[{"status":"affected","version":"V8.30","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7UM85 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7UT85 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7UT86 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7UT87 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7VE85 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 7VK87 (CP300)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1)","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 Communication Module ETH-BD-2FO","versions":[{"status":"affected","version":"V7.80","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPROTEC 5 Compact 7SX800 (CP050)","versions":[{"status":"affected","version":"V8.70","lessThan":"V9.30","versionType":"custom"}],"defaultStatus":"unknown"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-726834.html"}]}]}}