{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-38355","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","requesterUserId":"bc31a57b-b1a5-40e2-9263-67c0ae8a3b8a","dateReserved":"2022-09-29T14:08:03.143Z","datePublished":"2022-12-13T21:12:06.551Z","dateUpdated":"2025-04-16T16:04:52.712Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"SVMPC1 ","vendor":"Daikin","versions":[{"lessThanOrEqual":"2.1.22","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"SVMPC2","vendor":"Daikin","versions":[{"lessThanOrEqual":"1.2.3","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Chizuru Toyama from TXOne Networks reported these vulnerabilities to CISA."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to \n\n<span style=\"background-color: rgb(255, 255, 255);\">attackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication.</span>\n\n"}],"value":"Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to \n\nattackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication.\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-284","description":"CWE-284 Improper Access Control","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2022-12-13T21:12:06.551Z"},"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-284-02"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\nDaikin Holdings Singapore Pte Ltd. has released an update that will \nautomatically install if the SVM controller is enabled. No user \noperation is required. \n\n<br>"}],"value":"Daikin Holdings Singapore Pte Ltd. has released an update that will \nautomatically install if the SVM controller is enabled. No user \noperation is required. \n\n\n"}],"source":{"discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T10:54:03.383Z"},"title":"CVE Program Container","references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-284-02","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-16T15:53:21.791214Z","id":"CVE-2022-38355","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-04-16T16:04:52.712Z"}}]}}