{"containers":{"cna":{"affected":[{"product":"EcoStruxure Control Expert","vendor":"Schneider Electric","versions":[{"lessThanOrEqual":"15.1","status":"affected","version":"HF001","versionType":"custom"}]}],"descriptions":[{"lang":"en","value":"A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior)."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":5.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-119","description":"CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2022-09-13T09:35:12.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"tags":["x_refsource_MISC"],"url":"https://www.se.com/us/en/download/document/SEVD-2022-221-03/"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2022-37302","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"EcoStruxure Control Expert","version":{"version_data":[{"version_affected":"<=","version_name":"HF001","version_value":"15.1"}]}}]},"vendor_name":"Schneider Electric"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior)."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":5.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer"}]}]},"references":{"reference_data":[{"name":"https://www.se.com/us/en/download/document/SEVD-2022-221-03/","refsource":"MISC","url":"https://www.se.com/us/en/download/document/SEVD-2022-221-03/"}]},"source":{"discovery":"UNKNOWN"}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T10:29:20.575Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.se.com/us/en/download/document/SEVD-2022-221-03/"}]}]},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2022-37302","datePublished":"2022-09-13T09:35:12.000Z","dateReserved":"2022-08-01T00:00:00.000Z","dateUpdated":"2024-08-03T10:29:20.575Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}