{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-3684","assignerOrgId":"e383dce4-0c27-4495-91c4-0db157728d17","state":"PUBLISHED","assignerShortName":"Hitachi Energy","dateReserved":"2022-10-26T06:02:30.400Z","datePublished":"2023-03-28T12:49:36.714Z","dateUpdated":"2025-02-19T15:27:23.084Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"SDM600","vendor":"Hitachi Energy","versions":[{"status":"unaffected","version":"SDM600 1.3"},{"lessThanOrEqual":"SDM600 1.2.*","status":"affected","version":"SDM600 1.2","versionType":"custom"},{"lessThanOrEqual":"SDM600 1.1.*","status":"affected","version":"SDM600 1.1","versionType":"custom"},{"lessThanOrEqual":"SDM600 1.0.*","status":"affected","version":"SDM600 1.0","versionType":"custom"}]}],"datePublic":"2023-03-28T12:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"A vulnerability exists in a SDM600 endpoint.<br>An attacker could exploit this vulnerability by running multiple parallel requests, the SDM600 web services become busy rendering the application unresponsive.<br>This issue affects:&nbsp;All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291)<br><br> \n\nList of CPEs:\n\n<br><ul><li>cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:*</li><li>cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*</li></ul>"}],"value":"A vulnerability exists in a SDM600 endpoint.\nAn attacker could exploit this vulnerability by running multiple parallel requests, the SDM600 web services become busy rendering the application unresponsive.\nThis issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291)\n\n \n\nList of CPEs:\n\n\n  *  cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*\n\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-404","description":"CWE-404 Improper Resource Shutdown or Release","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"e383dce4-0c27-4495-91c4-0db157728d17","shortName":"Hitachi Energy","dateUpdated":"2023-03-28T12:49:36.714Z"},"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000138&LanguageCode=en&DocumentPartId=&Action=Launch"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The vulnerability is remediated in SDM600 1.3.0.1339.<br>Please update to SDM600 1.3.0.1339 version or apply mitigation as described in the Mitigation Factors/Workarounds Section.<br><br>"}],"value":"The vulnerability is remediated in SDM600 1.3.0.1339.\nPlease update to SDM600 1.3.0.1339 version or apply mitigation as described in the Mitigation Factors/Workarounds Section.\n\n"}],"source":{"discovery":"INTERNAL"},"title":"SDM600 endpoint vulnerability ","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Apply mitigation as described in the cybersecurity advisory Mitigation Factors/Workarounds Section."}],"value":"Apply mitigation as described in the cybersecurity advisory Mitigation Factors/Workarounds Section."}],"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T01:14:03.269Z"},"title":"CVE Program Container","references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000138&LanguageCode=en&DocumentPartId=&Action=Launch","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-19T15:27:14.520212Z","id":"CVE-2022-3684","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-02-19T15:27:23.084Z"}}]}}