{"containers":{"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"In Das U-Boot through 2022.07-rc5, an integer signedness error and resultant stack-based buffer overflow in the \"i2c md\" command enables the corruption of the return address pointer of the do_i2c_md function."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2022-06-29T23:48:50.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"tags":["x_refsource_MISC"],"url":"https://lists.denx.de/pipermail/u-boot/2022-June/486113.html"},{"tags":["x_refsource_MISC"],"url":"https://github.com/u-boot/u-boot/commit/8f8c04bf1ebbd2f72f1643e7ad9617dafa6e5409"},{"tags":["x_refsource_MISC"],"url":"https://source.denx.de/u-boot/u-boot/-/commit/8f8c04bf1ebbd2f72f1643e7ad9617dafa6e5409"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2022-34835","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In Das U-Boot through 2022.07-rc5, an integer signedness error and resultant stack-based buffer overflow in the \"i2c md\" command enables the corruption of the return address pointer of the do_i2c_md function."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"https://lists.denx.de/pipermail/u-boot/2022-June/486113.html","refsource":"MISC","url":"https://lists.denx.de/pipermail/u-boot/2022-June/486113.html"},{"name":"https://github.com/u-boot/u-boot/commit/8f8c04bf1ebbd2f72f1643e7ad9617dafa6e5409","refsource":"MISC","url":"https://github.com/u-boot/u-boot/commit/8f8c04bf1ebbd2f72f1643e7ad9617dafa6e5409"},{"name":"https://source.denx.de/u-boot/u-boot/-/commit/8f8c04bf1ebbd2f72f1643e7ad9617dafa6e5409","refsource":"MISC","url":"https://source.denx.de/u-boot/u-boot/-/commit/8f8c04bf1ebbd2f72f1643e7ad9617dafa6e5409"}]}}},"adp":[{"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://lists.denx.de/pipermail/u-boot/2022-June/486113.html"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://github.com/u-boot/u-boot/commit/8f8c04bf1ebbd2f72f1643e7ad9617dafa6e5409"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://source.denx.de/u-boot/u-boot/-/commit/8f8c04bf1ebbd2f72f1643e7ad9617dafa6e5409"},{"url":"https://lists.debian.org/debian-lts-announce/2025/05/msg00001.html"}],"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2025-11-03T19:27:09.290Z"}},{"x_adpType":"supplier","providerMetadata":{"orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP","dateUpdated":"2026-05-12T10:12:28.638Z"},"affected":[{"vendor":"Siemens","product":"RUGGEDCOM ROX MX5000","versions":[{"status":"affected","version":"0","lessThan":"V2.17.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM ROX MX5000RE","versions":[{"status":"affected","version":"0","lessThan":"V2.17.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1400","versions":[{"status":"affected","version":"0","lessThan":"V2.17.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1500","versions":[{"status":"affected","version":"0","lessThan":"V2.17.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1501","versions":[{"status":"affected","version":"0","lessThan":"V2.17.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1510","versions":[{"status":"affected","version":"0","lessThan":"V2.17.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1511","versions":[{"status":"affected","version":"0","lessThan":"V2.17.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1512","versions":[{"status":"affected","version":"0","lessThan":"V2.17.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1524","versions":[{"status":"affected","version":"0","lessThan":"V2.17.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1536","versions":[{"status":"affected","version":"0","lessThan":"V2.17.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX5000","versions":[{"status":"affected","version":"0","lessThan":"V2.17.1","versionType":"custom"}],"defaultStatus":"unknown"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-577017.html"}]}]},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2022-34835","datePublished":"2022-06-29T23:48:51.000Z","dateReserved":"2022-06-29T00:00:00.000Z","dateUpdated":"2026-05-12T10:12:28.638Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"}