{"containers":{"cna":{"affected":[{"product":"Mendix Applications using Mendix 9","vendor":"Siemens","versions":[{"status":"affected","version":"All versions >= V9.11 < V9.15"}]},{"product":"Mendix Applications using Mendix 9 (V9.12)","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V9.12.3"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Mendix Applications using Mendix 9 (All versions >= V9.11 < V9.15), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.3). An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-74","description":"CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2022-07-12T10:07:22.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"tags":["x_refsource_MISC"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2022-34466","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Mendix Applications using Mendix 9","version":{"version_data":[{"version_value":"All versions >= V9.11 < V9.15"}]}},{"product_name":"Mendix Applications using Mendix 9 (V9.12)","version":{"version_data":[{"version_value":"All versions < V9.12.3"}]}}]},"vendor_name":"Siemens"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in Mendix Applications using Mendix 9 (All versions >= V9.11 < V9.15), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.3). An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')"}]}]},"references":{"reference_data":[{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf","refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T09:15:15.104Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2022-34466","datePublished":"2022-07-12T10:07:22.000Z","dateReserved":"2022-06-24T00:00:00.000Z","dateUpdated":"2024-08-03T09:15:15.104Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}