{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"state":"PUBLISHED","cveId":"CVE-2022-32748","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","dateUpdated":"2025-02-05T20:07:23.903Z","dateReserved":"2022-06-09T00:00:00.000Z","datePublished":"2023-01-30T00:00:00.000Z"},"containers":{"cna":{"datePublic":"2022-06-14T00:00:00.000Z","providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2023-01-30T00:00:00.000Z"},"descriptions":[{"lang":"en","value":"A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)"}],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure™ Cybersecurity Admin Expert (CAE)","versions":[{"version":"All","status":"affected","lessThan":"2.2","versionType":"custom"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.9,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"type":"CWE","lang":"en","description":"CWE-295 Improper Certificate Validation","cweId":"CWE-295"}]}],"x_generator":{"engine":"Vulnogram 0.0.9"},"source":{"discovery":"UNKNOWN"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T07:46:45.261Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-05T19:52:27.920514Z","id":"CVE-2022-32748","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-02-05T20:07:23.903Z"}}]}}