{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-3192","assignerOrgId":"2b718523-d88f-4f37-9bbd-300c20644bf9","state":"PUBLISHED","assignerShortName":"ABB","dateReserved":"2022-09-13T05:57:45.421Z","datePublished":"2023-03-31T16:13:13.149Z","dateUpdated":"2025-02-11T18:40:07.850Z"},"containers":{"cna":{"affected":[{"collectionURL":"https://abb.com/plc","defaultStatus":"unknown","packageName":"PM5xx","product":"AC500 V2","vendor":"ABB","versions":[{"lessThan":"2.8.6","status":"affected","version":"2.0.0","versionType":"release"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"ABB thanks the following for working with us to help protect customers:  CVE-2022-3192: Parul Sindhwad and Dr. Faruk Kazi of CoE CNDS lab, VJTI, Mumbai (India) for reporting this vulnerability following coordinated disclosure."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.<p>This issue affects AC500 V2: from 2.0.0 before 2.8.6.</p>"}],"value":"Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.\n\n"}],"impacts":[{"capecId":"CAPEC-220","descriptions":[{"lang":"en","value":"CAPEC-220 Client-Server Protocol Manipulation"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-754","description":"CWE-754 Improper Check for Unusual or Exceptional Conditions","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"2b718523-d88f-4f37-9bbd-300c20644bf9","shortName":"ABB","dateUpdated":"2023-09-13T03:57:46.530Z"},"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162&LanguageCode=en&DocumentPartId=&Action=Launch"}],"source":{"discovery":"EXTERNAL"},"title":" Improper Check for Unusual or Exceptional Conditions","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<div>Use the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. <br></div><div>This protocol/port is not affected by the DoS impact of the vulnerability.<br></div>"}],"value":"Use the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \n\n\nThis protocol/port is not affected by the DoS impact of the vulnerability.\n\n\n"}],"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T01:00:10.643Z"},"title":"CVE Program Container","references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162&LanguageCode=en&DocumentPartId=&Action=Launch","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-11T18:39:53.320995Z","id":"CVE-2022-3192","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-02-11T18:40:07.850Z"}}]}}