{"containers":{"cna":{"affected":[{"product":"ILC 1x0","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"ILC 1x1","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"ILC 1x1 GSM/GPRS","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"ILC 3xx","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"AXC 1050","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"AXC 1050 XC","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"AXC 3050","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"RFC 480S PN 4TX","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"RFC 470 PN 3TX","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"RFC 470S PN 3TX","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"RFC 460R PN 3TX","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"RFC 460R PN 3TX-S","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"RFC 430 ETH-IB","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"RFC 450 ETH-IB","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"PC WORX SRT","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"PC WORX RT BASIC","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]},{"product":"FC 350 PCI ETH","vendor":"PHOENIX CONTACT","versions":[{"status":"affected","version":"All Versions"}]}],"credits":[{"lang":"en","value":"This vulnerability was reported by Forescout."}],"datePublic":"2022-06-20T00:00:00.000Z","descriptions":[{"lang":"en","value":"An unauthenticated, remote attacker could upload malicious logic to devices based on ProConOS/ProConOS eCLR in order to gain full control over the device."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-345","description":"CWE-345 Insufficient Verification of Data Authenticity","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2022-06-21T08:00:19.000Z","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","shortName":"CERTVDE"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://cert.vde.com/en/advisories/VDE-2022-025/"}],"source":{"advisory":"VDE-2022-026","discovery":"UNKNOWN"},"title":"Insufficient Verification of Data Vulnerability in PHOENIX CONTACT classic line industrial controllers","x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"info@cert.vde.com","DATE_PUBLIC":"2022-06-20T07:00:00.000Z","ID":"CVE-2022-31800","STATE":"PUBLIC","TITLE":"Insufficient Verification of Data Vulnerability in PHOENIX CONTACT classic line industrial controllers"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"ILC 1x0","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"ILC 1x1","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"ILC 1x1 GSM/GPRS","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"ILC 3xx","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"AXC 1050","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"AXC 1050 XC","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"AXC 3050","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"RFC 480S PN 4TX","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"RFC 470 PN 3TX","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"RFC 470S PN 3TX","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"RFC 460R PN 3TX","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"RFC 460R PN 3TX-S","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"RFC 430 ETH-IB","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"RFC 450 ETH-IB","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"PC WORX SRT","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"PC WORX RT BASIC","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}},{"product_name":"FC 350 PCI ETH","version":{"version_data":[{"version_affected":"=","version_name":"All Versions","version_value":"All Versions"}]}}]},"vendor_name":"PHOENIX CONTACT"}]}},"credit":[{"lang":"eng","value":"This vulnerability was reported by Forescout."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An unauthenticated, remote attacker could upload malicious logic to devices based on ProConOS/ProConOS eCLR in order to gain full control over the device."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-345 Insufficient Verification of Data Authenticity"}]}]},"references":{"reference_data":[{"name":"https://cert.vde.com/en/advisories/VDE-2022-025/","refsource":"CONFIRM","url":"https://cert.vde.com/en/advisories/VDE-2022-025/"}]},"source":{"advisory":"VDE-2022-026","discovery":"UNKNOWN"}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T07:26:01.318Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert.vde.com/en/advisories/VDE-2022-025/"}]}]},"cveMetadata":{"assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","assignerShortName":"CERTVDE","cveId":"CVE-2022-31800","datePublished":"2022-06-21T08:00:19.264Z","dateReserved":"2022-05-30T00:00:00.000Z","dateUpdated":"2024-09-16T16:54:13.463Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}