{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-3157","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","state":"PUBLISHED","assignerShortName":"Rockwell","requesterUserId":"20b06643-9bf3-4d1d-a98d-f8db99f95a31","dateReserved":"2022-09-07T19:00:02.431Z","datePublished":"2022-12-16T20:35:55.689Z","dateUpdated":"2025-04-16T14:32:17.798Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"CompactLogix 5370","vendor":"Rockwell Automation","versions":[{"lessThanOrEqual":"33","status":"affected","version":"20","versionType":"Major"}]},{"defaultStatus":"unaffected","product":"Compact GuardLogix","vendor":"Rockwell Automation","versions":[{"lessThanOrEqual":"33","status":"affected","version":"28","versionType":"Major"}]},{"defaultStatus":"unaffected","product":"ControlLogix 5570","vendor":"Rockwell Automation","versions":[{"lessThanOrEqual":"33","status":"affected","version":"20","versionType":"Major"}]},{"defaultStatus":"unaffected","product":"ControlLogix 5570 Redundancy","vendor":"Rockwell Automation","versions":[{"lessThanOrEqual":"33","status":"affected","version":"20","versionType":"Major"}]},{"defaultStatus":"unaffected","product":"GuardLogix 5570","vendor":"Rockwell Automation","versions":[{"lessThanOrEqual":"33","status":"affected","version":"20","versionType":"Major"}]}],"datePublic":"2022-12-15T15:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">A vulnerability exists in the Rockwell Automation controllers that allows a malformed CIP request to cause a major non-recoverable fault (MNRF) and a denial-of-service condition (DOS). </span>\n\n"}],"value":"\nA vulnerability exists in the Rockwell Automation controllers that allows a malformed CIP request to cause a major non-recoverable fault (MNRF) and a denial-of-service condition (DOS). \n\n"}],"impacts":[{"capecId":"CAPEC-123","descriptions":[{"lang":"en","value":"CAPEC-123 Buffer Manipulation"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.6,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","description":"CWE-20 Improper Input Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"b73dd486-f505-4403-b634-40b078b177f0","shortName":"Rockwell","dateUpdated":"2022-12-16T20:35:55.689Z"},"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137757"}],"source":{"discovery":"UNKNOWN"},"title":"Rockwell Automation GuardLogix and ControlLogix controllers Vulnerable to Denial-Of-Service Attack","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T01:00:10.589Z"},"title":"CVE Program Container","references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137757","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-16T14:31:37.602806Z","id":"CVE-2022-3157","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-04-16T14:32:17.798Z"}}]}}