{"containers":{"cna":{"affected":[{"product":"LNL-X2210","vendor":"LenelS2","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LNL-X2220","vendor":"LenelS2","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LNL-X3300","vendor":"LenelS2","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LNL-X4420","vendor":"LenelS2","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LNL-4420","vendor":"LenelS2","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"S2-LP-1501","vendor":"LenelS2","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"S2-LP-1502","vendor":"LenelS2","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"S2-LP-2500","vendor":"LenelS2","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"S2-LP-4502","vendor":"LenelS2","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LP1501","vendor":"HID Mercury","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LP1502","vendor":"HID Mercury","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LP2500","vendor":"HID Mercury","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LP4502","vendor":"HID Mercury","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"EP4502","vendor":"HID Mercury","versions":[{"lessThan":"1.271","status":"affected","version":"ALL","versionType":"custom"}]}],"credits":[{"lang":"en","value":"Sam Quinn @eAyeP and Steve Povolny @spovolny from Trellix Threat Labs"}],"datePublic":"2022-06-02T00:00:00.000Z","descriptions":[{"lang":"en","value":"An authenticated attacker can upload a file with a filename including “..” and “/” to achieve the ability to upload the desired file anywhere on the filesystem. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.271. This allows a malicious actor to overwrite sensitive system files and install a startup service to gain remote access to the underlaying Linux operating system with root privileges."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.1,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-22","description":"CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2022-06-06T16:39:56.000Z","orgId":"e24e6442-3ae1-4538-a7b8-7ac95586db8f","shortName":"Carrier"},"references":[{"tags":["x_refsource_MISC"],"url":"https://www.corporate.carrier.com/product-security/advisories-resources/"}],"solutions":[{"lang":"en","value":"Update to the latest version of firmware"}],"source":{"advisory":"CARR-PSA-006-0522","discovery":"EXTERNAL"},"title":"Arbitrary file write via authenticated OSDP file upload","workarounds":[{"lang":"en","value":"Disable the controller's Web Server.  \nWhen the controller is configured to disable web access, you cannot remotely login into the controller’s web page.\n1. Login to controller web pages\n2. Go to “Users” Tab\n3. Near bottom of the Users page, check option to “Disable Web Server”\n4. Then select “Submit” at the bottom of the page\n5. Then select “Apply Settings” tab\n6. And on that page, select button “Apply Settings, Reboot”\nThe Controller will apply the new setting and reboot. Web login will be disabled until switch 1 is physically turned ON, on the controller."}],"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productsecurity@carrier.com","DATE_PUBLIC":"2022-06-02T22:00:00.000Z","ID":"CVE-2022-31483","STATE":"PUBLIC","TITLE":"Arbitrary file write via authenticated OSDP file upload"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"LNL-X2210","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"LNL-X2220","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"LNL-X3300","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"LNL-X4420","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"LNL-4420","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"S2-LP-1501","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"S2-LP-1502","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"S2-LP-2500","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"S2-LP-4502","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}}]},"vendor_name":"LenelS2"},{"product":{"product_data":[{"product_name":"LP1501","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"LP1502","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"LP2500","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"LP4502","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}},{"product_name":"EP4502","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.271"}]}}]},"vendor_name":"HID Mercury"}]}},"credit":[{"lang":"eng","value":"Sam Quinn @eAyeP and Steve Povolny @spovolny from Trellix Threat Labs"}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An authenticated attacker can upload a file with a filename including “..” and “/” to achieve the ability to upload the desired file anywhere on the filesystem. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.271. This allows a malicious actor to overwrite sensitive system files and install a startup service to gain remote access to the underlaying Linux operating system with root privileges."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.1,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"}]}]},"references":{"reference_data":[{"name":"https://www.corporate.carrier.com/product-security/advisories-resources/","refsource":"MISC","url":"https://www.corporate.carrier.com/product-security/advisories-resources/"}]},"solution":[{"lang":"en","value":"Update to the latest version of firmware"}],"source":{"advisory":"CARR-PSA-006-0522","discovery":"EXTERNAL"},"work_around":[{"lang":"en","value":"Disable the controller's Web Server.  \nWhen the controller is configured to disable web access, you cannot remotely login into the controller’s web page.\n1. Login to controller web pages\n2. Go to “Users” Tab\n3. Near bottom of the Users page, check option to “Disable Web Server”\n4. Then select “Submit” at the bottom of the page\n5. Then select “Apply Settings” tab\n6. And on that page, select button “Apply Settings, Reboot”\nThe Controller will apply the new setting and reboot. Web login will be disabled until switch 1 is physically turned ON, on the controller."}]}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T07:19:06.090Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.corporate.carrier.com/product-security/advisories-resources/"}]}]},"cveMetadata":{"assignerOrgId":"e24e6442-3ae1-4538-a7b8-7ac95586db8f","assignerShortName":"Carrier","cveId":"CVE-2022-31483","datePublished":"2022-06-06T16:39:56.305Z","dateReserved":"2022-05-23T00:00:00.000Z","dateUpdated":"2024-09-16T18:55:31.907Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}