{"containers":{"cna":{"affected":[{"product":"LNL-X2210","vendor":"LenelS2","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LNL-X2220","vendor":"LenelS2","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LNL-X3300","vendor":"LenelS2","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LNL-X4420","vendor":"LenelS2","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LNL-4420","vendor":"LenelS2","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"S2-LP-1501","vendor":"LenelS2","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"S2-LP-1502","vendor":"LenelS2","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"S2-LP-2500","vendor":"LenelS2","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"S2-LP-4502","vendor":"LenelS2","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LP1501","vendor":"HID Mercury","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LP1502","vendor":"HID Mercury","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LP2500","vendor":"HID Mercury","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"LP4502","vendor":"HID Mercury","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]},{"product":"EP4502","vendor":"HID Mercury","versions":[{"lessThan":"1.29","status":"affected","version":"ALL","versionType":"custom"}]}],"credits":[{"lang":"en","value":"Sam Quinn @eAyeP and Steve Povolny @spovolny from Trellix Threat Labs"}],"datePublic":"2022-06-02T00:00:00.000Z","descriptions":[{"lang":"en","value":"An unauthenticated attacker can send a specially crafted unauthenticated HTTP request to the device that can overflow a buffer. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.29. The overflowed data leads to segmentation fault and ultimately a denial-of-service condition, causing the device to reboot. The impact of this vulnerability is that an unauthenticated attacker could leverage this flaw to cause the target device to become unresponsive. An attacker could automate this attack to achieve persistent DoS, effectively rendering the target controller useless."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-120","description":"CWE-120 Buffer Overflow","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2022-06-06T16:39:22.000Z","orgId":"e24e6442-3ae1-4538-a7b8-7ac95586db8f","shortName":"Carrier"},"references":[{"tags":["x_refsource_MISC"],"url":"https://www.corporate.carrier.com/product-security/advisories-resources/"}],"solutions":[{"lang":"en","value":"Update to the latest version of firmware"}],"source":{"advisory":"CARR-PSA-006-0522","discovery":"EXTERNAL"},"title":"Denial-of-Service via internal structure overflow","workarounds":[{"lang":"en","value":"Disable the controller's Web Server.  \nWhen the controller is configured to disable web access, you cannot remotely login into the controller’s web page.\n1. Login to controller web pages\n2. Go to “Users” Tab\n3. Near bottom of the Users page, check option to “Disable Web Server”\n4. Then select “Submit” at the bottom of the page\n5. Then select “Apply Settings” tab\n6. And on that page, select button “Apply Settings, Reboot”\nThe Controller will apply the new setting and reboot. Web login will be disabled until switch 1 is physically turned ON, on the controller."}],"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productsecurity@carrier.com","DATE_PUBLIC":"2022-06-02T22:00:00.000Z","ID":"CVE-2022-31482","STATE":"PUBLIC","TITLE":"Denial-of-Service via internal structure overflow"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"LNL-X2210","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"LNL-X2220","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"LNL-X3300","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"LNL-X4420","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"LNL-4420","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"S2-LP-1501","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"S2-LP-1502","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"S2-LP-2500","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"S2-LP-4502","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}}]},"vendor_name":"LenelS2"},{"product":{"product_data":[{"product_name":"LP1501","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"LP1502","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"LP2500","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"LP4502","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}},{"product_name":"EP4502","version":{"version_data":[{"version_affected":"<","version_name":"ALL","version_value":"1.29"}]}}]},"vendor_name":"HID Mercury"}]}},"credit":[{"lang":"eng","value":"Sam Quinn @eAyeP and Steve Povolny @spovolny from Trellix Threat Labs"}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An unauthenticated attacker can send a specially crafted unauthenticated HTTP request to the device that can overflow a buffer. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.29. The overflowed data leads to segmentation fault and ultimately a denial-of-service condition, causing the device to reboot. The impact of this vulnerability is that an unauthenticated attacker could leverage this flaw to cause the target device to become unresponsive. An attacker could automate this attack to achieve persistent DoS, effectively rendering the target controller useless."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-120 Buffer Overflow"}]}]},"references":{"reference_data":[{"name":"https://www.corporate.carrier.com/product-security/advisories-resources/","refsource":"MISC","url":"https://www.corporate.carrier.com/product-security/advisories-resources/"}]},"solution":[{"lang":"en","value":"Update to the latest version of firmware"}],"source":{"advisory":"CARR-PSA-006-0522","discovery":"EXTERNAL"},"work_around":[{"lang":"en","value":"Disable the controller's Web Server.  \nWhen the controller is configured to disable web access, you cannot remotely login into the controller’s web page.\n1. Login to controller web pages\n2. Go to “Users” Tab\n3. Near bottom of the Users page, check option to “Disable Web Server”\n4. Then select “Submit” at the bottom of the page\n5. Then select “Apply Settings” tab\n6. And on that page, select button “Apply Settings, Reboot”\nThe Controller will apply the new setting and reboot. Web login will be disabled until switch 1 is physically turned ON, on the controller."}]}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T07:19:05.847Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.corporate.carrier.com/product-security/advisories-resources/"}]}]},"cveMetadata":{"assignerOrgId":"e24e6442-3ae1-4538-a7b8-7ac95586db8f","assignerShortName":"Carrier","cveId":"CVE-2022-31482","datePublished":"2022-06-06T16:39:22.500Z","dateReserved":"2022-05-23T00:00:00.000Z","dateUpdated":"2024-09-17T01:00:48.176Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}