{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-3007","assignerOrgId":"66834db9-ab24-42b4-be80-296b2e40335c","state":"PUBLISHED","assignerShortName":"CERT-In","dateReserved":"2022-08-26T09:47:49.013Z","datePublished":"2023-10-31T11:18:23.411Z","dateUpdated":"2024-08-03T00:53:00.582Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Syska SW100 Smartwatch","vendor":"Syska Led Lights Pvt Ltd","versions":[{"lessThanOrEqual":"V2","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"This vulnerability is reported by Shakir Zari from Payatu Security Consulting Pvt Ltd., Maharashtra, India."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The vulnerability exists in Syska SW100 Smartwatch due to an improper implementation and/or configuration of Nordic Device Firmware Update (DFU) which is used for performing Over-The-Air (OTA) firmware updates on the Bluetooth Low Energy (BLE) devices. An unauthenticated attacker could exploit this vulnerability by setting arbitrary values to handle on the vulnerable device over Bluetooth.<br><br>Successful exploitation of this vulnerability could allow the attacker to perform firmware update, device reboot or data manipulation on the target device.<br>"}],"value":"The vulnerability exists in Syska SW100 Smartwatch due to an improper implementation and/or configuration of Nordic Device Firmware Update (DFU) which is used for performing Over-The-Air (OTA) firmware updates on the Bluetooth Low Energy (BLE) devices. An unauthenticated attacker could exploit this vulnerability by setting arbitrary values to handle on the vulnerable device over Bluetooth.\n\nSuccessful exploitation of this vulnerability could allow the attacker to perform firmware update, device reboot or data manipulation on the target device.\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-862","description":"CWE-862 Missing Authorization","lang":"en","type":"CWE"}]}],"references":[{"url":"https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01&VLCODE=CIVN-2023-0333"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Apply mitigations as per vendor instructions or discontinue use of the product if mitigations are unavailable."}],"value":"Apply mitigations as per vendor instructions or discontinue use of the product if mitigations are unavailable."}],"source":{"discovery":"UNKNOWN"},"tags":["unsupported-when-assigned"],"title":"Unauthorized Access Vulnerability in Syska SW100 Smartwatch","providerMetadata":{"orgId":"66834db9-ab24-42b4-be80-296b2e40335c","shortName":"CERT-In","dateUpdated":"2023-10-31T11:18:23.411Z"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T00:53:00.582Z"},"title":"CVE Program Container","references":[{"url":"https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01&VLCODE=CIVN-2023-0333","tags":["x_transferred"]}]}]}}