{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-29832","assignerOrgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","state":"PUBLISHED","assignerShortName":"Mitsubishi","requesterUserId":"520cc88b-a1c8-44f6-9154-21a4d74c769f","dateReserved":"2022-04-27T20:47:43.445Z","datePublished":"2022-11-24T23:37:41.044Z","dateUpdated":"2025-04-25T17:36:39.764Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"GX Works3","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.015R and later"}]},{"defaultStatus":"unaffected","product":"GX Works2","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"all versions"}]},{"defaultStatus":"unaffected","product":"GX Developer","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"8.40S and later"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting."}],"value":"Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting."}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":3.7,"baseSeverity":"LOW","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-316","description":"CWE-316 Cleartext Storage of Sensitive Information in Memory","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","shortName":"Mitsubishi","dateUpdated":"2023-05-31T06:40:22.640Z"},"references":[{"tags":["vendor-advisory"],"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"},{"tags":["government-resource"],"url":"https://jvn.jp/vu/JVNVU97244961"},{"tags":["government-resource"],"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T06:33:42.792Z"},"title":"CVE Program Container","references":[{"tags":["vendor-advisory","x_transferred"],"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"},{"tags":["government-resource","x_transferred"],"url":"https://jvn.jp/vu/JVNVU97244961"},{"tags":["government-resource","x_transferred"],"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-25T17:36:25.700934Z","id":"CVE-2022-29832","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-04-25T17:36:39.764Z"}}]}}