{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"state":"PUBLISHED","cveId":"CVE-2022-22731","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","dateUpdated":"2025-02-05T20:09:04.898Z","dateReserved":"2022-01-06T00:00:00.000Z","datePublished":"2023-01-30T00:00:00.000Z"},"containers":{"cna":{"datePublic":"2022-06-14T00:00:00.000Z","providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2023-01-30T00:00:00.000Z"},"descriptions":[{"lang":"en","value":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)"}],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure Power Commission","versions":[{"version":"All","status":"affected","lessThan":"V2.22","versionType":"custom"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"type":"CWE","lang":"en","description":"CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')","cweId":"CWE-22"}]}],"x_generator":{"engine":"Vulnogram 0.0.9"},"source":{"discovery":"UNKNOWN"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T03:21:48.950Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-05T19:50:48.313706Z","id":"CVE-2022-22731","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-02-05T20:09:04.898Z"}}]}}