{"containers":{"cna":{"affected":[{"product":"CODESYS Control RTE (SL)","vendor":"CODESYS","versions":[{"lessThan":"V3.5.17.40","status":"affected","version":"V3","versionType":"custom"}]},{"product":"CODESYS Control RTE (for Beckhoff CX) SL","vendor":"CODESYS","versions":[{"lessThan":"V3.5.17.40","status":"affected","version":"V3","versionType":"custom"}]},{"product":"CODESYS Control Win (SL)","vendor":"CODESYS","versions":[{"lessThan":"V3.5.17.40","status":"affected","version":"V3","versionType":"custom"}]},{"product":"CODESYS HMI (SL)","vendor":"CODESYS","versions":[{"lessThan":"V3.5.17.40","status":"affected","version":"V3","versionType":"custom"}]},{"product":"CODESYS Development System V3","vendor":"CODESYS","versions":[{"lessThan":"V3.5.17.40","status":"affected","version":"V3","versionType":"custom"}]},{"product":"CODESYS Control Runtime System Toolkit","vendor":"CODESYS","versions":[{"lessThan":"V3.5.17.40","status":"affected","version":"V3","versionType":"custom"}]},{"product":"CODESYS Embedded Target Visu Toolkit","vendor":"CODESYS","versions":[{"lessThan":"V3.5.17.40","status":"affected","version":"V3","versionType":"custom"}]},{"product":"CODESYS Remote Target Visu Toolkit","vendor":"CODESYS","versions":[{"lessThan":"V3.5.17.40","status":"affected","version":"V3","versionType":"custom"}]},{"product":"CODESYS Control for BeagleBone SL","vendor":"CODESYS","versions":[{"lessThan":"V4.5.0.0","status":"affected","version":"V4","versionType":"custom"}]},{"product":"CODESYS Control for Beckhoff CX9020 SL","vendor":"CODESYS","versions":[{"lessThan":"V4.5.0.0","status":"affected","version":"V4","versionType":"custom"}]},{"product":"CODESYS Control for emPC-A/iMX6 SL","vendor":"CODESYS","versions":[{"lessThan":"V4.5.0.0","status":"affected","version":"V4","versionType":"custom"}]},{"product":"CODESYS Control for IOT2000 SL","vendor":"CODESYS","versions":[{"lessThan":"V4.5.0.0","status":"affected","version":"V4","versionType":"custom"}]},{"product":"CODESYS Control for Linux SL","vendor":"CODESYS","versions":[{"lessThan":"V4.5.0.0","status":"affected","version":"V4","versionType":"custom"}]},{"product":"CODESYS Control for PFC100 SL","vendor":"CODESYS","versions":[{"lessThan":"V4.5.0.0","status":"affected","version":"V4","versionType":"custom"}]},{"product":"CODESYS Control for PFC200 SL","vendor":"CODESYS","versions":[{"lessThan":"V4.5.0.0","status":"affected","version":"V4","versionType":"custom"}]},{"product":"CODESYS Control for PLCnext SL","vendor":"CODESYS","versions":[{"lessThan":"V4.5.0.0","status":"affected","version":"V4","versionType":"custom"}]},{"product":"CODESYS Control for Raspberry Pi SL","vendor":"CODESYS","versions":[{"lessThan":"V4.5.0.0","status":"affected","version":"V4","versionType":"custom"}]},{"product":"CODESYS Control for WAGO Touch Panels 600 SL","vendor":"CODESYS","versions":[{"lessThan":"V4.5.0.0","status":"affected","version":"V4","versionType":"custom"}]}],"datePublic":"2022-06-01T00:00:00.000Z","descriptions":[{"lang":"en","value":"A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-668","description":"CWE-668 Exposure of Resource to Wrong Sphere","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2022-05-12T07:45:29.000Z","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","shortName":"CERTVDE"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download="}],"source":{"discovery":"UNKNOWN"},"title":"A component of the CODESYS Control runtime system allows read and write access to configuration files","x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"info@cert.vde.com","DATE_PUBLIC":"2022-06-01T10:00:00.000Z","ID":"CVE-2022-22515","STATE":"PUBLIC","TITLE":"A component of the CODESYS Control runtime system allows read and write access to configuration files"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"CODESYS Control RTE (SL)","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Control RTE (for Beckhoff CX) SL","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Control Win (SL)","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS HMI (SL)","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Development System V3","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Control Runtime System Toolkit","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Embedded Target Visu Toolkit","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Remote Target Visu Toolkit","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Control for BeagleBone SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for Beckhoff CX9020 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for emPC-A/iMX6 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for IOT2000 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for Linux SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for PFC100 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for PFC200 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for PLCnext SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for Raspberry Pi SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for WAGO Touch Panels 600 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}}]},"vendor_name":"CODESYS"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-668 Exposure of Resource to Wrong Sphere"}]}]},"references":{"reference_data":[{"name":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download=","refsource":"CONFIRM","url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download="}]},"source":{"discovery":"UNKNOWN"}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T03:14:55.437Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download="}]}]},"cveMetadata":{"assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","assignerShortName":"CERTVDE","cveId":"CVE-2022-22515","datePublished":"2022-04-07T18:21:16.280Z","dateReserved":"2022-01-03T00:00:00.000Z","dateUpdated":"2024-09-16T17:59:22.215Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}