{"containers":{"cna":{"affected":[{"product":"3D-A1000 Dimensioning System","vendor":"Cognex","versions":[{"lessThanOrEqual":"1.0.3 (3354)","status":"affected","version":"all","versionType":"custom"}]}],"credits":[{"lang":"en","value":"Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA."}],"descriptions":[{"lang":"en","value":"The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","description":"CWE-306 Missing Authentication for Critical Function","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2022-09-06T22:19:13.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"}],"source":{"discovery":"UNKNOWN"},"title":"Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function","x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2022-1368","STATE":"PUBLIC","TITLE":"Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"3D-A1000 Dimensioning System","version":{"version_data":[{"version_affected":"<=","version_name":"all","version_value":"1.0.3 (3354)"}]}}]},"vendor_name":"Cognex"}]}},"credit":[{"lang":"eng","value":"Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-306 Missing Authentication for Critical Function"}]}]},"references":{"reference_data":[{"name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03","refsource":"MISC","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"}]},"source":{"discovery":"UNKNOWN"}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T00:03:05.837Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-16T15:53:38.376179Z","id":"CVE-2022-1368","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-04-16T16:10:43.133Z"}}]},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2022-1368","datePublished":"2022-09-06T22:19:13.000Z","dateReserved":"2022-04-14T00:00:00.000Z","dateUpdated":"2025-04-16T16:10:43.133Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}