{"containers":{"cna":{"affected":[{"product":"Simcenter Femap V2020.2","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"Simcenter Femap V2021.1","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15085, ZDI-CAN-15289, ZDI-CAN-15602)"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","description":"CWE-121: Stack-based Buffer Overflow","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2022-02-11T18:07:07.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"tags":["x_refsource_MISC"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf"},{"tags":["x_refsource_MISC"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-311/"},{"tags":["x_refsource_MISC"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-312/"},{"tags":["x_refsource_MISC"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-313/"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2021-46158","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Simcenter Femap V2020.2","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"Simcenter Femap V2021.1","version":{"version_data":[{"version_value":"All versions"}]}}]},"vendor_name":"Siemens"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15085, ZDI-CAN-15289, ZDI-CAN-15602)"}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-121: Stack-based Buffer Overflow"}]}]},"references":{"reference_data":[{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf","refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-22-311/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-22-311/"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-22-312/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-22-312/"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-22-313/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-22-313/"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T05:02:10.856Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-311/"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-312/"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-313/"}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2021-46158","datePublished":"2022-02-09T15:17:23.000Z","dateReserved":"2022-01-07T00:00:00.000Z","dateUpdated":"2024-08-04T05:02:10.856Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}