{"containers":{"cna":{"affected":[{"product":"CP-8000 MASTER MODULE WITH I/O -25/+70°C","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V16.20"}]},{"product":"CP-8000 MASTER MODULE WITH I/O -40/+70°C","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V16.20"}]},{"product":"CP-8021 MASTER MODULE","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V16.20"}]},{"product":"CP-8022 MASTER MODULE WITH GPRS","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V16.20"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-798","description":"CWE-798: Use of Hard-coded Credentials","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2022-01-11T11:27:17.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"tags":["x_refsource_MISC"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2021-45033","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"CP-8000 MASTER MODULE WITH I/O -25/+70°C","version":{"version_data":[{"version_value":"All versions < V16.20"}]}},{"product_name":"CP-8000 MASTER MODULE WITH I/O -40/+70°C","version":{"version_data":[{"version_value":"All versions < V16.20"}]}},{"product_name":"CP-8021 MASTER MODULE","version":{"version_data":[{"version_value":"All versions < V16.20"}]}},{"product_name":"CP-8022 MASTER MODULE WITH GPRS","version":{"version_data":[{"version_value":"All versions < V16.20"}]}}]},"vendor_name":"Siemens"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-798: Use of Hard-coded Credentials"}]}]},"references":{"reference_data":[{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf","refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T04:32:13.621Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf"}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2021-45033","datePublished":"2022-01-11T11:27:17.000Z","dateReserved":"2021-12-13T00:00:00.000Z","dateUpdated":"2024-08-04T04:32:13.621Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}