{"containers":{"cna":{"affected":[{"product":"WinProladder","vendor":"FATEK Automation","versions":[{"lessThanOrEqual":"3.30_24518","status":"affected","version":"All","versionType":"custom"}]}],"datePublic":"2021-11-16T00:00:00.000Z","descriptions":[{"lang":"en","value":"FATEK WinProladder Versions 3.30_24518 and prior are vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","description":"CWE-787 Out-of-bounds Write","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2022-01-13T14:07:05.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-320-01"},{"tags":["x_refsource_MISC"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-030/"},{"tags":["x_refsource_MISC"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-033/"},{"tags":["x_refsource_MISC"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-028/"}],"solutions":[{"lang":"en","value":"FATEK Automation has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of these affected products are invited to contact FATEK customer support for additional information."}],"source":{"advisory":"ICSA-21-320-01","discovery":"UNKNOWN"},"title":"FATEK Automation WinProladder","x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2021-11-16T18:56:00.000Z","ID":"CVE-2021-43554","STATE":"PUBLIC","TITLE":"FATEK Automation WinProladder"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"WinProladder","version":{"version_data":[{"version_affected":"<=","version_name":"All","version_value":"3.30_24518"}]}}]},"vendor_name":"FATEK Automation"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"FATEK WinProladder Versions 3.30_24518 and prior are vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-787 Out-of-bounds Write"}]}]},"references":{"reference_data":[{"name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-320-01","refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-320-01"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-22-030/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-22-030/"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-22-033/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-22-033/"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-22-028/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-22-028/"}]},"solution":[{"lang":"en","value":"FATEK Automation has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of these affected products are invited to contact FATEK customer support for additional information."}],"source":{"advisory":"ICSA-21-320-01","discovery":"UNKNOWN"}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T04:03:08.244Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-320-01"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-030/"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-033/"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-028/"}]}]},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2021-43554","datePublished":"2021-12-28T18:17:44.936Z","dateReserved":"2021-11-08T00:00:00.000Z","dateUpdated":"2024-09-16T17:38:43.627Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}