{"containers":{"cna":{"affected":[{"product":"FL MGUARD","vendor":"PHOENIX CONTACT","versions":[{"lessThan":"FL MGUARD 1102 (No. 1153079)*","status":"affected","version":"1.4.0","versionType":"custom"},{"lessThan":"FL MGUARD 1105 (No. 1153078)*","status":"affected","version":"1.4.0","versionType":"custom"}]}],"credits":[{"lang":"en","value":"This vulnerability was discovered by a key customer. We kindly appreciate the coordinated disclosure of this vulnerability by the finder."}],"datePublic":"2021-11-10T00:00:00.000Z","descriptions":[{"lang":"en","value":"In Phoenix Contact FL MGUARD 1102 and 1105 in Versions 1.4.0, 1.4.1 and 1.5.0 the remote logging functionality is impaired by the lack of memory release for data structures from syslog-ng when remote logging is active"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-401","description":"CWE-401 Improper Release of Memory Before Removing Last Reference","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-11-10T11:22:05.000Z","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","shortName":"CERTVDE"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://cert.vde.com/en/advisories/VDE-2021-046/"}],"solutions":[{"lang":"en","value":"PHOENIX CONTACT recomments to upgrade to firmware version 1.5.1 (or any later version)."}],"source":{"advisory":"VDE-2021-046","discovery":"EXTERNAL"},"title":"Phoenix Contact: FL MGUARD lack of memory release in remote logging functionality","workarounds":[{"lang":"en","value":"To prevent the possibility of an attack, it is recommended to deactivate remote logging."}],"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"info@cert.vde.com","DATE_PUBLIC":"2021-11-10T11:00:00.000Z","ID":"CVE-2021-34598","STATE":"PUBLIC","TITLE":"Phoenix Contact: FL MGUARD lack of memory release in remote logging functionality"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"FL MGUARD","version":{"version_data":[{"version_affected":">=","version_name":"FL MGUARD 1102 (No. 1153079)","version_value":"1.4.0"},{"version_affected":"<=","version_name":"FL MGUARD 1102 (No. 1153079)","version_value":"1.5.0 +1"},{"version_affected":">=","version_name":"FL MGUARD 1105 (No. 1153078)","version_value":"1.4.0"},{"version_affected":"<=","version_name":"FL MGUARD 1105 (No. 1153078)","version_value":"1.5.0 +1"}]}}]},"vendor_name":"PHOENIX CONTACT"}]}},"credit":[{"lang":"eng","value":"This vulnerability was discovered by a key customer. We kindly appreciate the coordinated disclosure of this vulnerability by the finder."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In Phoenix Contact FL MGUARD 1102 and 1105 in Versions 1.4.0, 1.4.1 and 1.5.0 the remote logging functionality is impaired by the lack of memory release for data structures from syslog-ng when remote logging is active"}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-401 Improper Release of Memory Before Removing Last Reference"}]}]},"references":{"reference_data":[{"name":"https://cert.vde.com/en/advisories/VDE-2021-046/","refsource":"CONFIRM","url":"https://cert.vde.com/en/advisories/VDE-2021-046/"}]},"solution":[{"lang":"en","value":"PHOENIX CONTACT recomments to upgrade to firmware version 1.5.1 (or any later version)."}],"source":{"advisory":"VDE-2021-046","discovery":"EXTERNAL"},"work_around":[{"lang":"en","value":"To prevent the possibility of an attack, it is recommended to deactivate remote logging."}]}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T00:19:47.409Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert.vde.com/en/advisories/VDE-2021-046/"}]}]},"cveMetadata":{"assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","assignerShortName":"CERTVDE","cveId":"CVE-2021-34598","datePublished":"2021-11-10T11:22:05.667Z","dateReserved":"2021-06-10T00:00:00.000Z","dateUpdated":"2024-09-16T18:39:35.785Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}