{"containers":{"cna":{"affected":[{"platforms":["Hardware"],"product":"SiteManager","vendor":"Secomea","versions":[{"lessThan":"9.5","status":"affected","version":"All","versionType":"custom"}]}],"descriptions":[{"lang":"en","value":"Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-284","description":"CWE-284 Improper Access Control","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-200","description":"CWE-200 Information Exposure","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-08-05T20:33:27.000Z","orgId":"f2815942-3388-4c08-ba09-6c15850fda90","shortName":"Secomea"},"references":[{"tags":["x_refsource_MISC"],"url":"https://www.secomea.com/support/cybersecurity-advisory"}],"source":{"defect":["RD-3776"],"discovery":"INTERNAL"},"title":"SiteManager troubleshooter allows access without authentication from local network","x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"VulnerabilityReporting@secomea.com","ID":"CVE-2021-32002","STATE":"PUBLIC","TITLE":"SiteManager troubleshooter allows access without authentication from local network"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SiteManager","version":{"version_data":[{"platform":"Hardware","version_affected":"<","version_name":"All","version_value":"9.5"}]}}]},"vendor_name":"Secomea"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-284 Improper Access Control"}]},{"description":[{"lang":"eng","value":"CWE-200 Information Exposure"}]}]},"references":{"reference_data":[{"name":"https://www.secomea.com/support/cybersecurity-advisory","refsource":"MISC","url":"https://www.secomea.com/support/cybersecurity-advisory"}]},"source":{"defect":["RD-3776"],"discovery":"INTERNAL"}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T23:17:27.964Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.secomea.com/support/cybersecurity-advisory"}]}]},"cveMetadata":{"assignerOrgId":"f2815942-3388-4c08-ba09-6c15850fda90","assignerShortName":"Secomea","cveId":"CVE-2021-32002","datePublished":"2021-08-05T20:33:27.000Z","dateReserved":"2021-05-03T00:00:00.000Z","dateUpdated":"2024-08-03T23:17:27.964Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}