{"containers":{"cna":{"affected":[{"product":"SINUMERIK Analyse MyCondition","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SINUMERIK Analyze MyPerformance","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SINUMERIK Analyze MyPerformance /OEE-Monitor","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SINUMERIK Analyze MyPerformance /OEE-Tuning","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SINUMERIK Integrate Client 02","vendor":"Siemens","versions":[{"status":"affected","version":"All versions >= V02.00.12 < 02.00.18"}]},{"product":"SINUMERIK Integrate Client 03","vendor":"Siemens","versions":[{"status":"affected","version":"All versions >= V03.00.12 < 03.00.18"}]},{"product":"SINUMERIK Integrate Client 04","vendor":"Siemens","versions":[{"status":"affected","version":"V04.00.02 and all versions >= V04.00.15 < 04.00.18"}]},{"product":"SINUMERIK Integrate for Production 4.1","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.1 SP10 HF3"}]},{"product":"SINUMERIK Integrate for Production 5.1","vendor":"Siemens","versions":[{"status":"affected","version":"V5.1"}]},{"product":"SINUMERIK Manage MyMachines","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SINUMERIK Manage MyMachines /Remote","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SINUMERIK Manage MyMachines /Spindel Monitor","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SINUMERIK Manage MyPrograms","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SINUMERIK Manage MyResources /Programs","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SINUMERIK Manage MyResources /Tools","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SINUMERIK Manage MyTools","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SINUMERIK Operate V4.8","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.8 SP8"}]},{"product":"SINUMERIK Operate V4.93","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.93 HF7"}]},{"product":"SINUMERIK Operate V4.94","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.94 HF5"}]},{"product":"SINUMERIK Optimize MyProgramming /NX-Cam Editor","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-295","description":"CWE-295: Improper Certificate Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-07-30T18:51:21.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"tags":["x_refsource_MISC"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf"},{"tags":["x_refsource_MISC"],"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2021-31892","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SINUMERIK Analyse MyCondition","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Analyze MyPerformance","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Analyze MyPerformance /OEE-Monitor","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Analyze MyPerformance /OEE-Tuning","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Integrate Client 02","version":{"version_data":[{"version_value":"All versions >= V02.00.12 < 02.00.18"}]}},{"product_name":"SINUMERIK Integrate Client 03","version":{"version_data":[{"version_value":"All versions >= V03.00.12 < 03.00.18"}]}},{"product_name":"SINUMERIK Integrate Client 04","version":{"version_data":[{"version_value":"V04.00.02 and all versions >= V04.00.15 < 04.00.18"}]}},{"product_name":"SINUMERIK Integrate for Production 4.1","version":{"version_data":[{"version_value":"All versions < V4.1 SP10 HF3"}]}},{"product_name":"SINUMERIK Integrate for Production 5.1","version":{"version_data":[{"version_value":"V5.1"}]}},{"product_name":"SINUMERIK Manage MyMachines","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyMachines /Remote","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyMachines /Spindel Monitor","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyPrograms","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyResources /Programs","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyResources /Tools","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyTools","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Operate V4.8","version":{"version_data":[{"version_value":"All versions < V4.8 SP8"}]}},{"product_name":"SINUMERIK Operate V4.93","version":{"version_data":[{"version_value":"All versions < V4.93 HF7"}]}},{"product_name":"SINUMERIK Operate V4.94","version":{"version_data":[{"version_value":"All versions < V4.94 HF5"}]}},{"product_name":"SINUMERIK Optimize MyProgramming /NX-Cam Editor","version":{"version_data":[{"version_value":"All versions"}]}}]},"vendor_name":"Siemens"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-295: Improper Certificate Validation"}]}]},"references":{"reference_data":[{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf","refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf"},{"name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04","refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T23:10:30.735Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04"}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2021-31892","datePublished":"2021-07-13T11:02:55.000Z","dateReserved":"2021-04-29T00:00:00.000Z","dateUpdated":"2024-08-03T23:10:30.735Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}