{"containers":{"cna":{"affected":[{"platforms":["SRX Series"],"product":"Junos OS","vendor":"Juniper Networks","versions":[{"lessThan":"20.4R1","status":"unaffected","version":"unspecified","versionType":"custom"},{"changes":[{"at":"20.4R2-S1, 20.4R3","status":"unaffected"}],"lessThan":"20.4*","status":"affected","version":"20.4R1","versionType":"custom"},{"lessThan":"21.1R1-S1, 21.1R2","status":"affected","version":"21.1","versionType":"custom"}]}],"configurations":[{"lang":"en","value":"The following minimal configuration is necessary: \n\n  [system services web-management http]\nor\n  [system services web-management https]"}],"datePublic":"2021-10-13T00:00:00.000Z","descriptions":[{"lang":"en","value":"Due to a Missing Authorization weakness and Insufficient Granularity of Access Control in a specific device configuration, a vulnerability exists in Juniper Networks Junos OS on SRX Series whereby an attacker who attempts to access J-Web administrative interfaces can successfully do so from any device interface regardless of the web-management configuration and filter rules which may otherwise protect access to J-Web. This issue affects: Juniper Networks Junos OS SRX Series 20.4 version 20.4R1 and later versions prior to 20.4R2-S1, 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2. This issue does not affect Juniper Networks Junos OS versions prior to 20.4R1."}],"exploits":[{"lang":"en","value":"Juniper SIRT is not aware of any malicious exploitation of this vulnerability."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:N","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-285","description":"CWE-285: Improper Authorization","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-862","description":"CWE-862: Missing Authorization","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-551","description":"CWE-551: Incorrect Behavior Order: Authorization Before Parsing and Canonicalization","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-939","description":"CWE-939: Improper Authorization in Handler for Custom URL Scheme","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-1220","description":"CWE-1220: Insufficient Granularity of Access Control","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-10-19T18:17:27.000Z","orgId":"8cbe9d5a-a066-4c94-8978-4b15efeae968","shortName":"juniper"},"references":[{"tags":["x_refsource_MISC"],"url":"https://kb.juniper.net/"}],"solutions":[{"lang":"en","value":"The following software releases have been updated to resolve this specific issue: 20.4R2-S1, 20.4R3, 21.1R1-S1, 21.1R2, 21.2R1, and all subsequent releases."}],"source":{"advisory":"JSA11252","defect":["1577816"],"discovery":"INTERNAL"},"title":"Junos OS: SRX Series: Under a specific device configuration an attacker can access the devices J-Web management services from any interface, regardless of security settings protecting the service","workarounds":[{"lang":"en","value":"There are no viable workarounds for this issue other than disabling J-Web."}],"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"sirt@juniper.net","DATE_PUBLIC":"2021-10-13T16:00:00.000Z","ID":"CVE-2021-31384","STATE":"PUBLIC","TITLE":"Junos OS: SRX Series: Under a specific device configuration an attacker can access the devices J-Web management services from any interface, regardless of security settings protecting the service"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Junos OS","version":{"version_data":[{"platform":"SRX Series","version_affected":">=","version_name":"20.4","version_value":"20.4R1"},{"platform":"SRX Series","version_affected":"<","version_name":"20.4","version_value":"20.4R2-S1, 20.4R3"},{"platform":"SRX Series","version_affected":"<","version_name":"21.1","version_value":"21.1R1-S1, 21.1R2"},{"platform":"SRX Series","version_affected":"!<","version_value":"20.4R1"}]}}]},"vendor_name":"Juniper Networks"}]}},"configuration":[{"lang":"en","value":"The following minimal configuration is necessary: \n\n  [system services web-management http]\nor\n  [system services web-management https]"}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Due to a Missing Authorization weakness and Insufficient Granularity of Access Control in a specific device configuration, a vulnerability exists in Juniper Networks Junos OS on SRX Series whereby an attacker who attempts to access J-Web administrative interfaces can successfully do so from any device interface regardless of the web-management configuration and filter rules which may otherwise protect access to J-Web. This issue affects: Juniper Networks Junos OS SRX Series 20.4 version 20.4R1 and later versions prior to 20.4R2-S1, 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2. This issue does not affect Juniper Networks Junos OS versions prior to 20.4R1."}]},"exploit":[{"lang":"en","value":"Juniper SIRT is not aware of any malicious exploitation of this vulnerability."}],"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-285: Improper Authorization"}]},{"description":[{"lang":"eng","value":"CWE-862: Missing Authorization"}]},{"description":[{"lang":"eng","value":"CWE-551: Incorrect Behavior Order: Authorization Before Parsing and Canonicalization"}]},{"description":[{"lang":"eng","value":"CWE-939: Improper Authorization in Handler for Custom URL Scheme"}]},{"description":[{"lang":"eng","value":"CWE-1220: Insufficient Granularity of Access Control"}]}]},"references":{"reference_data":[{"name":"https://kb.juniper.net/","refsource":"MISC","url":"https://kb.juniper.net/"}]},"solution":[{"lang":"en","value":"The following software releases have been updated to resolve this specific issue: 20.4R2-S1, 20.4R3, 21.1R1-S1, 21.1R2, 21.2R1, and all subsequent releases."}],"source":{"advisory":"JSA11252","defect":["1577816"],"discovery":"INTERNAL"},"work_around":[{"lang":"en","value":"There are no viable workarounds for this issue other than disabling J-Web."}]}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T22:55:53.778Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://kb.juniper.net/"}]}]},"cveMetadata":{"assignerOrgId":"8cbe9d5a-a066-4c94-8978-4b15efeae968","assignerShortName":"juniper","cveId":"CVE-2021-31384","datePublished":"2021-10-19T18:17:28.030Z","dateReserved":"2021-04-15T00:00:00.000Z","dateUpdated":"2024-09-16T17:37:44.972Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}