{"containers":{"cna":{"affected":[{"product":"SCALANCE X200-4P IRT","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE X201-3P IRT","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE X201-3P IRT PRO","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE X202-2 IRT","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE X202-2P IRT (incl. SIPLUS NET variant)","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE X202-2P IRT PRO","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE X204 IRT","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE X204 IRT PRO","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE X204-2 (incl. SIPLUS NET variant)","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X204-2FM","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X204-2LD (incl. SIPLUS NET variant)","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X204-2LD TS","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X204-2TS","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X206-1","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X206-1LD","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X208 (incl. SIPLUS NET variant)","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X208PRO","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X212-2 (incl. SIPLUS NET variant)","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X212-2LD","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X216","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE X224","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE XF201-3P IRT","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE XF202-2P IRT","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE XF204","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE XF204 IRT","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE XF204-2 (incl. SIPLUS NET variant)","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE XF204-2BA IRT","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < 5.5.1"}]},{"product":"SCALANCE XF206-1","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]},{"product":"SCALANCE XF208","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.5"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-122","description":"CWE-122: Heap-based Buffer Overflow","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-09-14T10:47:23.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"tags":["x_refsource_MISC"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2021-25668","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SCALANCE X200-4P IRT","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE X201-3P IRT","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE X201-3P IRT PRO","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE X202-2 IRT","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE X202-2P IRT (incl. SIPLUS NET variant)","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE X202-2P IRT PRO","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE X204 IRT","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE X204 IRT PRO","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE X204-2 (incl. SIPLUS NET variant)","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X204-2FM","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X204-2LD (incl. SIPLUS NET variant)","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X204-2LD TS","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X204-2TS","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X206-1","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X206-1LD","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X208 (incl. SIPLUS NET variant)","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X208PRO","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X212-2 (incl. SIPLUS NET variant)","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X212-2LD","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X216","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE X224","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE XF201-3P IRT","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE XF202-2P IRT","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE XF204","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE XF204 IRT","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE XF204-2 (incl. SIPLUS NET variant)","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE XF204-2BA IRT","version":{"version_data":[{"version_value":"All versions < 5.5.1"}]}},{"product_name":"SCALANCE XF206-1","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}},{"product_name":"SCALANCE XF208","version":{"version_data":[{"version_value":"All versions < V5.2.5"}]}}]},"vendor_name":"Siemens"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-122: Heap-based Buffer Overflow"}]}]},"references":{"reference_data":[{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf","refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T20:11:27.504Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf"}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2021-25668","datePublished":"2021-04-22T20:42:20.000Z","dateReserved":"2021-01-21T00:00:00.000Z","dateUpdated":"2024-08-03T20:11:27.504Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}