{"containers":{"cna":{"affected":[{"product":"myPRO","vendor":"mySCADA","versions":[{"lessThanOrEqual":"8.20.0","status":"affected","version":"All","versionType":"custom"}]}],"datePublic":"2021-12-21T00:00:00.000Z","descriptions":[{"lang":"en","value":"mySCADA myPRO: Versions 8.20.0 and prior has a feature where the password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":10,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 OS Command Injection","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-12-23T19:48:35.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"}],"solutions":[{"lang":"en","value":"mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."}],"source":{"advisory":"ICSA-21-355-01","discovery":"UNKNOWN"},"title":"mySCADA myPRO","x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2021-12-21T17:26:00.000Z","ID":"CVE-2021-23198","STATE":"PUBLIC","TITLE":"mySCADA myPRO"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"myPRO","version":{"version_data":[{"version_affected":"<=","version_name":"All","version_value":"8.20.0"}]}}]},"vendor_name":"mySCADA"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"mySCADA myPRO: Versions 8.20.0 and prior has a feature where the password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":10,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-78 OS Command Injection"}]}]},"references":{"reference_data":[{"name":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01","refsource":"MISC","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"}]},"solution":[{"lang":"en","value":"mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."}],"source":{"advisory":"ICSA-21-355-01","discovery":"UNKNOWN"}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T19:05:55.652Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"}]}]},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2021-23198","datePublished":"2021-12-23T19:48:35.400Z","dateReserved":"2021-12-03T00:00:00.000Z","dateUpdated":"2024-09-16T16:23:34.792Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}