{"containers":{"cna":{"affected":[{"product":"spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)","vendor":"n/a","versions":[{"status":"affected","version":"spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)"}]}],"descriptions":[{"lang":"en","value":"A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-669","description":"CWE-669: Incorrect Resource Transfer Between Spheres","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2022-02-11T17:40:34.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"tags":["x_refsource_MISC"],"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2021-22806","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)","version":{"version_data":[{"version_value":"spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)"}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-669: Incorrect Resource Transfer Between Spheres"}]}]},"references":{"reference_data":[{"name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01","refsource":"MISC","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T18:51:07.468Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01"}]}]},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2021-22806","datePublished":"2022-02-11T17:40:34.000Z","dateReserved":"2021-01-06T00:00:00.000Z","dateUpdated":"2024-08-03T18:51:07.468Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}