{"containers":{"cna":{"affected":[{"product":"PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)","vendor":"n/a","versions":[{"status":"affected","version":"EcoStruxure Power Build - Rapsody software V2.1.13 and prior."}]}],"descriptions":[{"lang":"en","value":"A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-319","description":"CWE-319: Cleartext transmission of sensitive information","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-02-19T15:14:25.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"tags":["x_refsource_MISC"],"url":"https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2021-22703","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)","version":{"version_data":[{"version_value":"EcoStruxure Power Build - Rapsody software V2.1.13 and prior."}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-319: Cleartext transmission of sensitive information"}]}]},"references":{"reference_data":[{"name":"https://www.se.com/ww/en/download/document/SEVD-2021-040-01/","refsource":"MISC","url":"https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T18:51:07.062Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"}]}]},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2021-22703","datePublished":"2021-02-19T15:14:25.000Z","dateReserved":"2021-01-06T00:00:00.000Z","dateUpdated":"2024-08-03T18:51:07.062Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}