{"containers":{"cna":{"affected":[{"product":"Advantech","vendor":"n/a","versions":[{"status":"affected","version":"Advantech R-SeeNet 2.4.12 (20.10.2020)"}]}],"descriptions":[{"lang":"en","value":"An OS Command Injection vulnerability exists in the ping.php script functionality of Advantech R-SeeNet v 2.4.12 (20.10.2020). A specially crafted HTTP request can lead to arbitrary OS command execution. An attacker can send a crafted HTTP request to trigger this vulnerability."}],"metrics":[{"cvssV3_0":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-08-05T20:03:59.000Z","orgId":"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b","shortName":"talos"},"references":[{"tags":["x_refsource_MISC"],"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1274"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"talos-cna@cisco.com","ID":"CVE-2021-21805","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Advantech","version":{"version_data":[{"version_value":"Advantech R-SeeNet 2.4.12 (20.10.2020)"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An OS Command Injection vulnerability exists in the ping.php script functionality of Advantech R-SeeNet v 2.4.12 (20.10.2020). A specially crafted HTTP request can lead to arbitrary OS command execution. An attacker can send a crafted HTTP request to trigger this vulnerability."}]},"impact":{"cvss":{"baseScore":9.8,"baseSeverity":"Critical","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"}]}]},"references":{"reference_data":[{"name":"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1274","refsource":"MISC","url":"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1274"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T18:23:29.592Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1274"}]}]},"cveMetadata":{"assignerOrgId":"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b","assignerShortName":"talos","cveId":"CVE-2021-21805","datePublished":"2021-08-05T20:03:59.000Z","dateReserved":"2021-01-04T00:00:00.000Z","dateUpdated":"2024-08-03T18:23:29.592Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}