{"containers":{"cna":{"affected":[{"product":"PowerFlex","vendor":"Dell","versions":[{"status":"affected","version":"3.5.x"}]}],"datePublic":"2021-07-01T00:00:00.000Z","descriptions":[{"lang":"en","value":"Dell EMC PowerFlex, v3.5.x contain a Cross-Site WebSocket Hijacking Vulnerability in the Presentation Server/WebUI. An unauthenticated attacker could potentially exploit this vulnerability by tricking the user into performing unwanted actions on the Presentation Server and perform which may lead to configuration changes."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-345","description":"CWE-345: Insufficient Verification of Data Authenticity","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-07-12T15:40:14.000Z","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell"},"references":[{"tags":["x_refsource_MISC"],"url":"https://www.dell.com/support/kbdoc/000189265"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"secure@dell.com","DATE_PUBLIC":"2021-07-01","ID":"CVE-2021-21588","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"PowerFlex","version":{"version_data":[{"version_affected":"=","version_value":"3.5.x"}]}}]},"vendor_name":"Dell"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Dell EMC PowerFlex, v3.5.x contain a Cross-Site WebSocket Hijacking Vulnerability in the Presentation Server/WebUI. An unauthenticated attacker could potentially exploit this vulnerability by tricking the user into performing unwanted actions on the Presentation Server and perform which may lead to configuration changes."}]},"impact":{"cvss":{"baseScore":6.5,"baseSeverity":"Medium","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-345: Insufficient Verification of Data Authenticity"}]}]},"references":{"reference_data":[{"name":"https://www.dell.com/support/kbdoc/000189265","refsource":"MISC","url":"https://www.dell.com/support/kbdoc/000189265"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T18:16:23.581Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.dell.com/support/kbdoc/000189265"}]}]},"cveMetadata":{"assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","assignerShortName":"dell","cveId":"CVE-2021-21588","datePublished":"2021-07-12T15:40:14.345Z","dateReserved":"2021-01-04T00:00:00.000Z","dateUpdated":"2024-09-17T00:15:37.249Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}