{"containers":{"cna":{"affected":[{"product":"UC20-WL2000-AC (No. 1334950000)","vendor":"Weidmüller","versions":[{"lessThanOrEqual":"1.9.0","status":"affected","version":"1.3.0","versionType":"custom"},{"lessThanOrEqual":"1.10.2","status":"affected","version":"1.10.0","versionType":"custom"},{"lessThanOrEqual":"1.12.1","status":"affected","version":"1.11.0","versionType":"custom"}]},{"product":"UC20-WL2000-IOT (No. 1334990000)","vendor":"Weidmüller","versions":[{"lessThanOrEqual":"1.9.0","status":"affected","version":"1.3.0","versionType":"custom"},{"lessThanOrEqual":"1.10.2","status":"affected","version":"1.10.0","versionType":"custom"},{"lessThanOrEqual":"1.12.1","status":"affected","version":"1.11.0","versionType":"custom"}]},{"product":"IOT-GW30 (No. 2682620000)","vendor":"Weidmüller","versions":[{"lessThanOrEqual":"1.9.0","status":"affected","version":"1.3.0","versionType":"custom"},{"lessThanOrEqual":"1.10.2","status":"affected","version":"1.10.0","versionType":"custom"},{"lessThanOrEqual":"1.12.1","status":"affected","version":"1.11.0","versionType":"custom"}]},{"product":"IOT-GW30-4G-EU (No. 2682630000)","vendor":"Weidmüller","versions":[{"lessThanOrEqual":"1.9.0","status":"affected","version":"1.3.0","versionType":"custom"},{"lessThanOrEqual":"1.10.2","status":"affected","version":"1.10.0","versionType":"custom"},{"lessThanOrEqual":"1.12.1","status":"affected","version":"1.11.0","versionType":"custom"}]}],"credits":[{"lang":"en","value":"Reported by Weidmüller."}],"datePublic":"2021-05-04T00:00:00.000Z","descriptions":[{"lang":"en","value":"In Weidmüller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.4,"baseSeverity":"CRITICAL","confidentialityImpact":"LOW","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-668","description":"CWE-668 Exposure of Resource to Wrong Sphere","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-05-13T13:45:25.000Z","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","shortName":"CERTVDE"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://cert.vde.com/en-us/advisories/vde-2021-016"}],"solutions":[{"lang":"en","value":"Weidmüller recommends upgrading affected devices to the current firmware version 1.12.3 or higher which fixes this vulnerability."}],"source":{"advisory":"VDE-2021-016","defect":["VDE-2021-016"],"discovery":"INTERNAL"},"title":"WEIDMUELLER: Accidentally open network port in u-controls and IoT-Gateways","workarounds":[{"lang":"en","value":"Restrict access to the network the device is connected to.\nDo not directly connect the device to the internet."}],"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"info@cert.vde.com","DATE_PUBLIC":"2021-05-04T10:00:00.000Z","ID":"CVE-2021-20999","STATE":"PUBLIC","TITLE":"WEIDMUELLER: Accidentally open network port in u-controls and IoT-Gateways"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"UC20-WL2000-AC (No. 1334950000)","version":{"version_data":[{"version_affected":"<=","version_name":"1.3.0","version_value":"1.9.0"},{"version_affected":"<=","version_name":"1.10.0","version_value":"1.10.2"},{"version_affected":"<=","version_name":"1.11.0","version_value":"1.12.1"}]}},{"product_name":"UC20-WL2000-IOT (No. 1334990000)","version":{"version_data":[{"version_affected":"<=","version_name":"1.3.0","version_value":"1.9.0"},{"version_affected":"<=","version_name":"1.10.0","version_value":"1.10.2"},{"version_affected":"<=","version_name":"1.11.0","version_value":"1.12.1"}]}},{"product_name":"IOT-GW30 (No. 2682620000)","version":{"version_data":[{"version_affected":"<=","version_name":"1.3.0","version_value":"1.9.0"},{"version_affected":"<=","version_name":"1.10.0","version_value":"1.10.2"},{"version_affected":"<=","version_name":"1.11.0","version_value":"1.12.1"}]}},{"product_name":"IOT-GW30-4G-EU (No. 2682630000)","version":{"version_data":[{"version_affected":"<=","version_name":"1.3.0","version_value":"1.9.0"},{"version_affected":"<=","version_name":"1.10.0","version_value":"1.10.2"},{"version_affected":"<=","version_name":"1.11.0","version_value":"1.12.1"}]}}]},"vendor_name":"Weidmüller"}]}},"credit":[{"lang":"eng","value":"Reported by Weidmüller."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In Weidmüller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.4,"baseSeverity":"CRITICAL","confidentialityImpact":"LOW","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-668 Exposure of Resource to Wrong Sphere"}]}]},"references":{"reference_data":[{"name":"https://cert.vde.com/en-us/advisories/vde-2021-016","refsource":"CONFIRM","url":"https://cert.vde.com/en-us/advisories/vde-2021-016"}]},"solution":[{"lang":"en","value":"Weidmüller recommends upgrading affected devices to the current firmware version 1.12.3 or higher which fixes this vulnerability."}],"source":{"advisory":"VDE-2021-016","defect":["VDE-2021-016"],"discovery":"INTERNAL"},"work_around":[{"lang":"en","value":"Restrict access to the network the device is connected to.\nDo not directly connect the device to the internet."}]}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-03T17:53:23.078Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert.vde.com/en-us/advisories/vde-2021-016"}]}]},"cveMetadata":{"assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","assignerShortName":"CERTVDE","cveId":"CVE-2021-20999","datePublished":"2021-05-13T13:45:25.284Z","dateReserved":"2020-12-17T00:00:00.000Z","dateUpdated":"2024-09-17T01:16:17.295Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}