{"containers":{"cna":{"affected":[{"product":"Solid Edge SE2020","vendor":"Siemens","versions":[{"status":"affected","version":"All Versions < SE2020MP12"}]},{"product":"Solid Edge SE2021","vendor":"Siemens","versions":[{"status":"affected","version":"All Versions < SE2021MP2"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","description":"CWE-787: Out-of-bounds Write","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-02-09T15:38:20.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"tags":["x_refsource_MISC"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"},{"tags":["x_refsource_MISC"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-052/"},{"tags":["x_refsource_MISC"],"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"},{"tags":["x_refsource_MISC"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-075/"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2020-28382","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Solid Edge SE2020","version":{"version_data":[{"version_value":"All Versions < SE2020MP12"}]}},{"product_name":"Solid Edge SE2021","version":{"version_data":[{"version_value":"All Versions < SE2021MP2"}]}}]},"vendor_name":"Siemens"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-787: Out-of-bounds Write"}]}]},"references":{"reference_data":[{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf","refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-21-052/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-21-052/"},{"name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04","refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-21-075/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-21-075/"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T16:33:59.191Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-052/"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-075/"}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2020-28382","datePublished":"2021-01-12T20:18:35.000Z","dateReserved":"2020-11-10T00:00:00.000Z","dateUpdated":"2024-08-04T16:33:59.191Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}