{"containers":{"cna":{"affected":[{"product":"Trailer Power Line Communications","vendor":"Multiple Vendors All trailer power line communications are affected.","versions":[{"status":"affected","version":"All trailer power line communications are affected."}]}],"descriptions":[{"lang":"en","value":"All trailer Power Line Communications are affected. PLC bus traffic can be sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-201","description":"EXPOSURE OF SENSITIVE INFORMATION THROUGH SENT DATA CWE-201","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2020-09-01T14:00:45.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01"}],"source":{"discovery":"UNKNOWN"},"title":"Trailer Power Line Communications vulnerability","x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2020-14514","STATE":"PUBLIC","TITLE":"Trailer Power Line Communications vulnerability"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Trailer Power Line Communications","version":{"version_data":[{"version_value":"All trailer power line communications are affected."}]}}]},"vendor_name":"Multiple Vendors All trailer power line communications are affected."}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"All trailer Power Line Communications are affected. PLC bus traffic can be sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"EXPOSURE OF SENSITIVE INFORMATION THROUGH SENT DATA CWE-201"}]}]},"references":{"reference_data":[{"name":"https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01","refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01"}]},"source":{"discovery":"UNKNOWN"}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T12:46:34.636Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01"}]}]},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2020-14514","datePublished":"2020-09-01T14:00:45.000Z","dateReserved":"2020-06-19T00:00:00.000Z","dateUpdated":"2024-08-04T12:46:34.636Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}