{"containers":{"cna":{"affected":[{"product":"U.motion Server","vendor":"Schneider Electric SE","versions":[{"status":"affected","version":"MEG6501-0001 - U.motion KNX server"},{"status":"affected","version":"MEG6501-0002 - U.motion KNX Server Plus"},{"status":"affected","version":"MEG6260-0410 - U.motion KNX Server Plus"},{"status":"affected","version":"Touch 10"},{"status":"affected","version":"MEG6260-0415 - U.motion KNX Server Plus"},{"status":"affected","version":"Touch 15"}]}],"descriptions":[{"lang":"en","value":"A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to send a crafted message to the target server, thereby causing arbitrary commands to be executed."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-134","description":"Format String: CWE-134","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2019-09-17T19:19:36.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2019-6840","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"U.motion Server","version":{"version_data":[{"version_value":"MEG6501-0001 - U.motion KNX server"},{"version_value":"MEG6501-0002 - U.motion KNX Server Plus"},{"version_value":"MEG6260-0410 - U.motion KNX Server Plus"},{"version_value":"Touch 10"},{"version_value":"MEG6260-0415 - U.motion KNX Server Plus"},{"version_value":"Touch 15"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to send a crafted message to the target server, thereby causing arbitrary commands to be executed."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Format String: CWE-134"}]}]},"references":{"reference_data":[{"name":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01","refsource":"CONFIRM","url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T20:31:04.390Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01"}]}]},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2019-6840","datePublished":"2019-09-17T19:19:36.000Z","dateReserved":"2019-01-25T00:00:00.000Z","dateUpdated":"2024-08-04T20:31:04.390Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}