{"containers":{"cna":{"affected":[{"product":"Magelis HMI Panels","vendor":"Schneider Electric SE","versions":[{"status":"affected","version":"all versions of HMIGTO"},{"status":"affected","version":"all versions of HMISTO"},{"status":"affected","version":"all versions of XBTGH"},{"status":"affected","version":"all versions of HMIGTU"},{"status":"affected","version":"all versions of HMIGTUX"},{"status":"affected","version":"all versions of HMISCU"},{"status":"affected","version":"all versions of HMISTU"},{"status":"affected","version":"all versions of XBTGT"},{"status":"affected","version":"all versions of HMIGXO"},{"status":"affected","version":"all versions of HMIGXU"}]}],"descriptions":[{"lang":"en","value":"A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-754","description":"CWE-754 – Improper Check for Unusual or Exceptional Conditions","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2019-10-02T12:13:24.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"},{"tags":["x_refsource_MISC"],"url":"https://security.cse.iitk.ac.in/responsible-disclosure"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2019-6833","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Magelis HMI Panels","version":{"version_data":[{"version_value":"all versions of HMIGTO"},{"version_value":"all versions of HMISTO"},{"version_value":"all versions of XBTGH"},{"version_value":"all versions of HMIGTU"},{"version_value":"all versions of HMIGTUX"},{"version_value":"all versions of HMISCU"},{"version_value":"all versions of HMISTU"},{"version_value":"all versions of XBTGT"},{"version_value":"all versions of XBTGT"},{"version_value":"all versions of HMIGXO"},{"version_value":"all versions of HMIGXU"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-754 – Improper Check for Unusual or Exceptional Conditions"}]}]},"references":{"reference_data":[{"name":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01","refsource":"CONFIRM","url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"},{"name":"https://security.cse.iitk.ac.in/responsible-disclosure","refsource":"MISC","url":"https://security.cse.iitk.ac.in/responsible-disclosure"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T20:31:04.400Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://security.cse.iitk.ac.in/responsible-disclosure"}]},{"metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":6.5,"attackVector":"NETWORK","baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H","integrityImpact":"NONE","userInteraction":"REQUIRED","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"NONE"}},{"other":{"type":"ssvc","content":{"timestamp":"2025-09-30T14:36:06.892056Z","id":"CVE-2019-6833","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-09-30T14:36:19.669Z"}}]},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2019-6833","datePublished":"2019-09-17T19:36:57.000Z","dateReserved":"2019-01-25T00:00:00.000Z","dateUpdated":"2025-09-30T14:36:19.669Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}