{"containers":{"cna":{"affected":[{"product":"LAquis SCADA","vendor":"LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME","versions":[{"status":"affected","version":"< 4.3.1.71"}]}],"datePublic":"2019-03-14T00:00:00.000Z","descriptions":[{"lang":"en","value":"Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","description":"Out-of-Bounds Write CWE-787","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2019-04-02T15:06:09.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01"},{"tags":["x_refsource_MISC"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-19-307/"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2019-6536","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"LAquis SCADA","version":{"version_data":[{"version_value":"< 4.3.1.71"}]}}]},"vendor_name":"LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Out-of-Bounds Write CWE-787"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-19-307/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-19-307/"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T20:23:21.362Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-19-307/"}]}]},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2019-6536","datePublished":"2019-03-27T15:25:23.000Z","dateReserved":"2019-01-22T00:00:00.000Z","dateUpdated":"2024-08-04T20:23:21.362Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}