{"containers":{"cna":{"affected":[{"product":"Solution Center","vendor":"Lenovo","versions":[{"lessThanOrEqual":"03.12.003","status":"affected","version":"unspecified","versionType":"custom"}]}],"credits":[{"lang":"en","value":"Lenovo would like to thank Takeshi Shiomitsu at Pen Test Partners for reporting this issue."}],"datePublic":"2019-08-20T00:00:00.000Z","descriptions":[{"lang":"en","value":"A vulnerability reported in Lenovo Solution Center version 03.12.003, which is no longer supported, could allow log files to be written to non-standard locations, potentially leading to privilege escalation. Lenovo ended support for Lenovo Solution Center and recommended that customers migrate to Lenovo Vantage or Lenovo Diagnostics in April 2018."}],"metrics":[{"cvssV3_0":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}}],"problemTypes":[{"descriptions":[{"description":"Privilege escalation","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2019-08-21T19:55:05.000Z","orgId":"da227ddf-6e25-4b41-b023-0f976dcaca4b","shortName":"lenovo"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://support.lenovo.com/solutions/LEN-27811"}],"solutions":[{"lang":"en","value":"Users should uninstall Lenovo Solution Center, using Programs and Features from the Control Panel, and migrate to Lenovo Vantage or Lenovo Diagnostics."}],"source":{"advisory":"LEN-27811","discovery":"UNKNOWN"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"psirt@lenovo.com","DATE_PUBLIC":"2019-08-20T16:00:00.000Z","ID":"CVE-2019-6177","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Solution Center","version":{"version_data":[{"affected":"<=","version_affected":"<=","version_value":"03.12.003"}]}}]},"vendor_name":"Lenovo"}]}},"credit":[{"lang":"eng","value":"Lenovo would like to thank Takeshi Shiomitsu at Pen Test Partners for reporting this issue."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability reported in Lenovo Solution Center version 03.12.003, which is no longer supported, could allow log files to be written to non-standard locations, potentially leading to privilege escalation. Lenovo ended support for Lenovo Solution Center and recommended that customers migrate to Lenovo Vantage or Lenovo Diagnostics in April 2018."}]},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Privilege escalation"}]}]},"references":{"reference_data":[{"name":"https://support.lenovo.com/solutions/LEN-27811","refsource":"CONFIRM","url":"https://support.lenovo.com/solutions/LEN-27811"}]},"solution":[{"lang":"en","value":"Users should uninstall Lenovo Solution Center, using Programs and Features from the Control Panel, and migrate to Lenovo Vantage or Lenovo Diagnostics."}],"source":{"advisory":"LEN-27811","discovery":"UNKNOWN"}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T20:16:23.987Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://support.lenovo.com/solutions/LEN-27811"}]}]},"cveMetadata":{"assignerOrgId":"da227ddf-6e25-4b41-b023-0f976dcaca4b","assignerShortName":"lenovo","cveId":"CVE-2019-6177","datePublished":"2019-08-21T19:55:05.766Z","dateReserved":"2019-01-11T00:00:00.000Z","dateUpdated":"2024-09-16T18:59:18.570Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}