{"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2023-04-11T09:01:51.207Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service."}],"affected":[{"vendor":"Siemens","product":"SCALANCE X200-4P IRT","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X201-3P IRT","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X201-3P IRT PRO","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X202-2IRT","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X202-2P IRT","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X202-2P IRT PRO","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X204-2","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X204-2FM","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X204-2LD","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X204-2LD TS","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X204-2TS","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X204IRT","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X204IRT PRO","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X206-1","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X206-1LD","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X208","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X208PRO","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X212-2","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X212-2LD","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X216","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X224","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (230V, coated)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (230V)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (24V, coated)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (24V)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 230V, coated)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 230V)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 24V, coated)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 24V)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X304-2FE","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X306-1LD FE","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (230V, coated)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (230V)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (24V, coated)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (24V)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 230V, coated)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 230V)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 24V, coated)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 24V)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-3","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-3","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-3LD","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X307-3LD","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2LD","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2LD","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2LH","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2LH","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2LH+","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2LH+","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2M","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2M","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2M PoE","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2M PoE","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2M TS","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X308-2M TS","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X310","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X310","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X310FE","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X310FE","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X320-1 FE","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X320-1-2LD FE","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X408-2","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF201-3P IRT","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF202-2P IRT","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF204","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF204-2","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF204-2BA IRT","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF204IRT","versions":[{"version":"All versions < V5.5.0","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF206-1","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF208","versions":[{"version":"All versions < V5.2.5","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-12M TS (24V)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-12M TS (24V)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (230V, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (230V, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (24V, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (24V, ports on rear)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE TS (24V, ports on front)","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 343-1 Advanced","versions":[{"version":"All versions","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 442-1 RNA","versions":[{"version":"All versions < V1.5.18","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 443-1","versions":[{"version":"All versions < V3.3","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 443-1","versions":[{"version":"All versions < V3.3","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 443-1 Advanced","versions":[{"version":"All versions < V3.3","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 443-1 RNA","versions":[{"version":"All versions < V1.5.18","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC RF180C","versions":[{"version":"All versions","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC RF182C","versions":[{"version":"All versions","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS NET CP 343-1 Advanced","versions":[{"version":"All versions","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS NET CP 443-1","versions":[{"version":"All versions < V3.3","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS NET CP 443-1 Advanced","versions":[{"version":"All versions < V3.3","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS NET SCALANCE X308-2","versions":[{"version":"All versions < V4.1.4","status":"affected"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:U/RC:C","baseScore":7.5,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-400","description":"CWE-400: Uncontrolled Resource Consumption","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf"}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T02:16:46.705Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf","tags":["x_transferred"]}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2019-19301","datePublished":"2020-04-14T19:50:54.000Z","dateReserved":"2019-11-26T00:00:00.000Z","dateUpdated":"2024-08-05T02:16:46.705Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}