{"containers":{"cna":{"affected":[{"product":"Cisco Small Business 220 Series Smart Plus Switches","vendor":"Cisco","versions":[{"lessThan":"1.1.4.4","status":"affected","version":"unspecified","versionType":"custom"}]}],"datePublic":"2019-08-06T00:00:00.000Z","descriptions":[{"lang":"en","value":"A vulnerability in the web management interface of Cisco Small Business 220 Series Smart Switches could allow an authenticated, remote attacker to perform a command injection attack. The vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a malicious request to certain parts of the web management interface. To send the malicious request, the attacker needs a valid login session in the web management interface as a privilege level 15 user. Depending on the configuration of the affected switch, the malicious request must be sent via HTTP or HTTPS. A successful exploit could allow the attacker to execute arbitrary shell commands with the privileges of the root user."}],"exploits":[{"lang":"en","value":"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."}],"metrics":[{"cvssV3_0":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","description":"CWE-20","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2019-10-01T22:06:04.000Z","orgId":"d1c1063e-7a18-46af-9102-31f8928bc633","shortName":"cisco"},"references":[{"name":"20190806 Cisco Small Business 220 Series Smart Switches Command Injection Vulnerability","tags":["vendor-advisory","x_refsource_CISCO"],"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190806-sb220-inject"},{"tags":["x_refsource_MISC"],"url":"http://packetstormsecurity.com/files/154667/Realtek-Managed-Switch-Controller-RTL83xx-Stack-Overflow.html"}],"source":{"advisory":"cisco-sa-20190806-sb220-inject","defect":[["CSCvo66557"]],"discovery":"INTERNAL"},"title":"Cisco Small Business 220 Series Smart Switches Command Injection Vulnerability","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"psirt@cisco.com","DATE_PUBLIC":"2019-08-06T14:00:00-0700","ID":"CVE-2019-1914","STATE":"PUBLIC","TITLE":"Cisco Small Business 220 Series Smart Switches Command Injection Vulnerability"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Cisco Small Business 220 Series Smart Plus Switches","version":{"version_data":[{"affected":"<","version_affected":"<","version_value":"1.1.4.4"}]}}]},"vendor_name":"Cisco"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability in the web management interface of Cisco Small Business 220 Series Smart Switches could allow an authenticated, remote attacker to perform a command injection attack. The vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a malicious request to certain parts of the web management interface. To send the malicious request, the attacker needs a valid login session in the web management interface as a privilege level 15 user. Depending on the configuration of the affected switch, the malicious request must be sent via HTTP or HTTPS. A successful exploit could allow the attacker to execute arbitrary shell commands with the privileges of the root user."}]},"exploit":[{"lang":"en","value":"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."}],"impact":{"cvss":{"baseScore":"7.2","vectorString":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-20"}]}]},"references":{"reference_data":[{"name":"20190806 Cisco Small Business 220 Series Smart Switches Command Injection Vulnerability","refsource":"CISCO","url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190806-sb220-inject"},{"name":"http://packetstormsecurity.com/files/154667/Realtek-Managed-Switch-Controller-RTL83xx-Stack-Overflow.html","refsource":"MISC","url":"http://packetstormsecurity.com/files/154667/Realtek-Managed-Switch-Controller-RTL83xx-Stack-Overflow.html"}]},"source":{"advisory":"cisco-sa-20190806-sb220-inject","defect":[["CSCvo66557"]],"discovery":"INTERNAL"}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T18:35:50.766Z"},"title":"CVE Program Container","references":[{"name":"20190806 Cisco Small Business 220 Series Smart Switches Command Injection Vulnerability","tags":["vendor-advisory","x_refsource_CISCO","x_transferred"],"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190806-sb220-inject"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://packetstormsecurity.com/files/154667/Realtek-Managed-Switch-Controller-RTL83xx-Stack-Overflow.html"}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-20T16:53:42.707370Z","id":"CVE-2019-1914","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-20T17:14:57.430Z"}}]},"cveMetadata":{"assignerOrgId":"d1c1063e-7a18-46af-9102-31f8928bc633","assignerShortName":"cisco","cveId":"CVE-2019-1914","datePublished":"2019-08-07T05:50:11.911Z","dateReserved":"2018-12-06T00:00:00.000Z","dateUpdated":"2024-11-20T17:14:57.430Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}