{"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2024-01-09T09:56:13.407Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The HTTP service (default port 5401/tcp) of the SiVMS/SiNVR Video Server\ncontains an authentication bypass vulnerability, even when properly\nconfigured with enforced authentication.\n\nA remote attacker with network access to the Video Server could \nexploit this vulnerability to read the SiVMS/SiNVR users database, including\nthe passwords of all users in obfuscated cleartext."}],"affected":[{"vendor":"Siemens","product":"SiNVR/SiVMS Video Server","versions":[{"version":"All versions < V5.0.0","status":"affected"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:F/RL:U/RC:C","baseScore":9.8,"baseSeverity":"CRITICAL"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-306","description":"CWE-306: Missing Authentication for Critical Function","type":"CWE"}]}],"references":[{"tags":["x_refsource_MISC"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T01:54:14.297Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2019-18339","datePublished":"2019-12-12T19:08:49.000Z","dateReserved":"2019-10-23T00:00:00.000Z","dateUpdated":"2024-08-05T01:54:14.297Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}