{"containers":{"cna":{"affected":[{"product":"SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)","vendor":"Siemens AG","versions":[{"status":"affected","version":"All versions < V3.X.17"}]},{"product":"SIMATIC TDC CP51M1","vendor":"Siemens AG","versions":[{"status":"affected","version":"All versions < V1.1.8"}]},{"product":"SIMATIC TDC CPU555","vendor":"Siemens AG","versions":[{"status":"affected","version":"All versions < V1.1.1"}]},{"product":"SINUMERIK 840D sl","vendor":"Siemens AG","versions":[{"status":"affected","version":"All versions < V4.8.6"}]},{"product":"SINUMERIK 840D sl","vendor":"Siemens AG","versions":[{"status":"affected","version":"All versions < V4.94"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-400","description":"CWE-400: Uncontrolled Resource Consumption","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2020-07-14T13:18:04.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"tags":["x_refsource_MISC"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2019-18336","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)","version":{"version_data":[{"version_value":"All versions < V3.X.17"}]}},{"product_name":"SIMATIC TDC CP51M1","version":{"version_data":[{"version_value":"All versions < V1.1.8"}]}},{"product_name":"SIMATIC TDC CPU555","version":{"version_data":[{"version_value":"All versions < V1.1.1"}]}},{"product_name":"SINUMERIK 840D sl","version":{"version_data":[{"version_value":"All versions < V4.8.6"}]}},{"product_name":"SINUMERIK 840D sl","version":{"version_data":[{"version_value":"All versions < V4.94"}]}}]},"vendor_name":"Siemens AG"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-400: Uncontrolled Resource Consumption"}]}]},"references":{"reference_data":[{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf","refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T01:54:14.382Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf"}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2019-18336","datePublished":"2020-03-10T19:16:17.000Z","dateReserved":"2019-10-23T00:00:00.000Z","dateUpdated":"2024-08-05T01:54:14.382Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}