{"containers":{"cna":{"affected":[{"platforms":["NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE"],"product":"Junos OS","vendor":"Juniper Networks","versions":[{"status":"unaffected","version":"15.1"},{"status":"unaffected","version":"16.2  16.2"},{"lessThan":"15.1F6-S12","status":"affected","version":"15.1F","versionType":"custom"},{"changes":[{"at":"16.1R6-S6, 16.1R7-S3","status":"unaffected"}],"lessThan":"16.1*","status":"affected","version":"16.1R6","versionType":"custom"},{"lessThan":"17.1R3","status":"affected","version":"17.1","versionType":"custom"},{"changes":[{"at":"17.2R3-S1","status":"unaffected"}],"lessThan":"17.2*","status":"affected","version":"17.2R1-S3, 17.2R3","versionType":"custom"},{"changes":[{"at":"17.3R3-S3","status":"unaffected"}],"lessThan":"17.3*","status":"affected","version":"17.3R1-S1, 17.3R2","versionType":"custom"},{"changes":[{"at":"17.4R1-S6, 17.4R2-S2, 17.4R3","status":"unaffected"}],"lessThan":"17.4*","status":"affected","version":"17.4R1","versionType":"custom"},{"lessThan":"18.1R2-S4, 18.1R3-S3","status":"affected","version":"18.1","versionType":"custom"},{"lessThan":"18.2R2","status":"affected","version":"18.2","versionType":"custom"},{"lessThan":"18.2X75-D40","status":"affected","version":"18.2X75","versionType":"custom"},{"lessThan":"18.3R1-S2, 18.3R2","status":"affected","version":"18.3","versionType":"custom"},{"lessThan":"18.4R1-S1, 18.4R2","status":"affected","version":"18.4","versionType":"custom"}]}],"configurations":[{"lang":"en","value":"To identify whether the device has NG-RE with vmhost, customer can run the following command:\n  > show vmhost status\n  Compute cluster: rainier-re-cc\n  Compute Node: rainier-re-cn, Online\nIf the \"show vmhost status\" is not supported, then the device does not have NG-RE with vmhost."}],"datePublic":"2019-10-09T00:00:00.000Z","descriptions":[{"lang":"en","value":"A path traversal vulnerability in NFX150 Series and QFX10K Series, EX9200 Series, MX Series and PTX Series devices with Next-Generation Routing Engine (NG-RE) allows a local authenticated user to read sensitive system files. This issue only affects NFX150 Series and QFX10K Series, EX9200 Series, MX Series and PTX Series with Next-Generation Routing Engine (NG-RE) which uses vmhost. This issue affects Juniper Networks Junos OS on NFX150 Series and QFX10K, EX9200 Series, MX Series and PTX Series with NG-RE and vmhost: 15.1F versions prior to 15.1F6-S12 16.1 versions starting from 16.1R6 and later releases, including the Service Releases, prior to 16.1R6-S6, 16.1R7-S3; 17.1 versions prior to 17.1R3; 17.2 versions starting from 17.2R1-S3, 17.2R3 and later releases, including the Service Releases, prior to 17.2R3-S1; 17.3 versions starting from 17.3R1-S1, 17.3R2 and later releases, including the Service Releases, prior to 17.3R3-S3; 17.4 versions starting from 17.4R1 and later releases, including the Service Releases, prior to 17.4R1-S6, 17.4R2-S2, 17.4R3; 18.1 versions prior to 18.1R2-S4, 18.1R3-S3; 18.2 versions prior to 18.2R2; 18.2X75 versions prior to 18.2X75-D40; 18.3 versions prior to 18.3R1-S2, 18.3R2; 18.4 versions prior to 18.4R1-S1, 18.4R2. This issue does not affect: Juniper Networks Junos OS 15.1 and 16.2."}],"exploits":[{"lang":"en","value":"Juniper SIRT is not aware of any malicious exploitation of this vulnerability."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"NONE","baseScore":5.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","version":"3.1"}}],"problemTypes":[{"descriptions":[{"description":"privilege escalation","lang":"en","type":"text"}]},{"descriptions":[{"description":"Improper Privilege Management.","lang":"en","type":"text"}]},{"descriptions":[{"cweId":"CWE-22","description":"CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-23","description":"CWE-23 Relative Path Traversal","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2019-10-09T19:26:18.000Z","orgId":"8cbe9d5a-a066-4c94-8978-4b15efeae968","shortName":"juniper"},"references":[{"tags":["x_refsource_MISC"],"url":"https://kb.juniper.net/JSA10975"}],"solutions":[{"lang":"en","value":"The following software releases have been updated to resolve these specific issues: 15.1F6-S12, 16.1R6-S6, 16.1R7-S3, 17.1R3, 17.2R3-S1, 17.3R3-S3, 17.4R1-S6, 17.4R2-S2, 17.4R3, 18.1R2-S4, 18.1R3-S3, 18.2R2, 18.2R3, 18.2X75-D40, 18.3R1-S2, 18.3R2, 18.4R1-S1, 18.4R2, 19.1R1, and all subsequent releases."}],"source":{"advisory":"JSA10975","defect":["1398333"],"discovery":"INTERNAL"},"title":"Junos OS: NFX150 Series, QFX10K Series, EX9200 Series, MX Series, PTX Series: Path traversal vulnerability in NFX150 and NG-RE leads to information disclosure.","workarounds":[{"lang":"en","value":"There are no known workarounds for this issue."}],"x_generator":{"engine":"Vulnogram 0.0.6"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"sirt@juniper.net","DATE_PUBLIC":"2019-10-09T16:00:00.000Z","ID":"CVE-2019-0074","STATE":"PUBLIC","TITLE":"Junos OS: NFX150 Series, QFX10K Series, EX9200 Series, MX Series, PTX Series: Path traversal vulnerability in NFX150 and NG-RE leads to information disclosure."},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Junos OS","version":{"version_data":[{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"<","version_name":"15.1F","version_value":"15.1F6-S12"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"!","version_name":"15.1","version_value":"15.1"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":">=","version_name":"16.1","version_value":"16.1R6"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"<","version_name":"16.1","version_value":"16.1R6-S6, 16.1R7-S3"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"!","version_name":"16.2","version_value":"16.2"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"<","version_name":"17.1","version_value":"17.1R3"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":">=","version_name":"17.2","version_value":"17.2R1-S3, 17.2R3"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"<","version_name":"17.2","version_value":"17.2R3-S1"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":">=","version_name":"17.3","version_value":"17.3R1-S1, 17.3R2"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"<","version_name":"17.3","version_value":"17.3R3-S3"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":">=","version_name":"17.4","version_value":"17.4R1"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"<","version_name":"17.4","version_value":"17.4R1-S6, 17.4R2-S2, 17.4R3"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"<","version_name":"18.1","version_value":"18.1R2-S4, 18.1R3-S3"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"<","version_name":"18.2","version_value":"18.2R2"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"<","version_name":"18.2X75","version_value":"18.2X75-D40"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"<","version_name":"18.3","version_value":"18.3R1-S2, 18.3R2"},{"platform":"NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE","version_affected":"<","version_name":"18.4","version_value":"18.4R1-S1, 18.4R2"}]}}]},"vendor_name":"Juniper Networks"}]}},"configuration":[{"lang":"en","value":"To identify whether the device has NG-RE with vmhost, customer can run the following command:\n  > show vmhost status\n  Compute cluster: rainier-re-cc\n  Compute Node: rainier-re-cn, Online\nIf the \"show vmhost status\" is not supported, then the device does not have NG-RE with vmhost."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A path traversal vulnerability in NFX150 Series and QFX10K Series, EX9200 Series, MX Series and PTX Series devices with Next-Generation Routing Engine (NG-RE) allows a local authenticated user to read sensitive system files. This issue only affects NFX150 Series and QFX10K Series, EX9200 Series, MX Series and PTX Series with Next-Generation Routing Engine (NG-RE) which uses vmhost. This issue affects Juniper Networks Junos OS on NFX150 Series and QFX10K, EX9200 Series, MX Series and PTX Series with NG-RE and vmhost: 15.1F versions prior to 15.1F6-S12 16.1 versions starting from 16.1R6 and later releases, including the Service Releases, prior to 16.1R6-S6, 16.1R7-S3; 17.1 versions prior to 17.1R3; 17.2 versions starting from 17.2R1-S3, 17.2R3 and later releases, including the Service Releases, prior to 17.2R3-S1; 17.3 versions starting from 17.3R1-S1, 17.3R2 and later releases, including the Service Releases, prior to 17.3R3-S3; 17.4 versions starting from 17.4R1 and later releases, including the Service Releases, prior to 17.4R1-S6, 17.4R2-S2, 17.4R3; 18.1 versions prior to 18.1R2-S4, 18.1R3-S3; 18.2 versions prior to 18.2R2; 18.2X75 versions prior to 18.2X75-D40; 18.3 versions prior to 18.3R1-S2, 18.3R2; 18.4 versions prior to 18.4R1-S1, 18.4R2. This issue does not affect: Juniper Networks Junos OS 15.1 and 16.2."}]},"exploit":[{"lang":"en","value":"Juniper SIRT is not aware of any malicious exploitation of this vulnerability."}],"generator":{"engine":"Vulnogram 0.0.6"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"NONE","baseScore":5.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"privilege escalation"}]},{"description":[{"lang":"eng","value":"Improper Privilege Management."}]},{"description":[{"lang":"eng","value":"CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"}]},{"description":[{"lang":"eng","value":"CWE-23 Relative Path Traversal"}]}]},"references":{"reference_data":[{"name":"https://kb.juniper.net/JSA10975","refsource":"MISC","url":"https://kb.juniper.net/JSA10975"}]},"solution":[{"lang":"en","value":"The following software releases have been updated to resolve these specific issues: 15.1F6-S12, 16.1R6-S6, 16.1R7-S3, 17.1R3, 17.2R3-S1, 17.3R3-S3, 17.4R1-S6, 17.4R2-S2, 17.4R3, 18.1R2-S4, 18.1R3-S3, 18.2R2, 18.2R3, 18.2X75-D40, 18.3R1-S2, 18.3R2, 18.4R1-S1, 18.4R2, 19.1R1, and all subsequent releases."}],"source":{"advisory":"JSA10975","defect":["1398333"],"discovery":"INTERNAL"},"work_around":[{"lang":"en","value":"There are no known workarounds for this issue."}]}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-04T17:37:07.350Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://kb.juniper.net/JSA10975"}]}]},"cveMetadata":{"assignerOrgId":"8cbe9d5a-a066-4c94-8978-4b15efeae968","assignerShortName":"juniper","cveId":"CVE-2019-0074","datePublished":"2019-10-09T19:26:18.153Z","dateReserved":"2018-10-11T00:00:00.000Z","dateUpdated":"2024-09-17T03:38:51.289Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}